Heinen & Hopman

Self-Contained Unit 90MA

Heinen & Hopman Self-Contained Unit 90MA — Marine self-contained (monobloc) air conditioning unit for cabins, control rooms, and common areas on ships and offshore platforms. Suitable for ducted and free-blow applications. Factory pre-charged; requires only water and electrical connections..

Components & Design

Component data being added…

Technical Data

cooling capacity kW 10.5–35.1
refrigerants R134a, R404a, R407
electrical supply 230V/380V/460V 3-phase 50/60 Hz

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Filter inspection and cleaning/replacement: check filter mats (e.g. P15/500) for clogging and differential pressure drop across filter section

Filter inspection and cleaning/replacement: check filter mats (e.g. P15/500) for clogging and differential pressure drop across filter section

Coil inspection: check heating and cooling coils for fouling, corrosion, and fin damage; verify water/refrigerant connections for leaks

Coil inspection: check heating and cooling coils for fouling, corrosion, and fin damage; verify water/refrigerant connections for leaks

Fan and motor check: inspect centrifugal fan blades for corrosion and mechanical wear, check belt tension or direct-drive coupling, verify vibration isolators a

Fan and motor check: inspect centrifugal fan blades for corrosion and mechanical wear, check belt tension or direct-drive coupling, verify vibration isolators and flexible connections

Drain pan and condensate drainage: inspect and clean condensate drain pan and drain lines to prevent microbial growth and blockage

Drain pan and condensate drainage: inspect and clean condensate drain pan and drain lines to prevent microbial growth and blockage

Damper and valve function: verify operation of fresh-air, return-air, and mixing dampers; check actuators and regulating valves for correct positioning

Damper and valve function: verify operation of fresh-air, return-air, and mixing dampers; check actuators and regulating valves for correct positioning

Electrical and controls inspection: check control starter panel, thermostats, hygrostats, solenoid valves, and safety interlocks; verify motor insulation class

Electrical and controls inspection: check control starter panel, thermostats, hygrostats, solenoid valves, and safety interlocks; verify motor insulation class IP54 rating integrity

Refrigerant circuit check (for Package Units HH-PU): verify refrigerant charge (R-407C/R-134a), compressor oil level, condenser and evaporator condition, and ch

Refrigerant circuit check (for Package Units HH-PU): verify refrigerant charge (R-407C/R-134a), compressor oil level, condenser and evaporator condition, and check for leaks

Casing and insulation integrity: inspect unit casing (EN 1886 compliant) for corrosion from salt air, check door seals and access panels, verify thermal insulat

Casing and insulation integrity: inspect unit casing (EN 1886 compliant) for corrosion from salt air, check door seals and access panels, verify thermal insulation (T2/TB2) is intact

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #152209 · ✓ still in production

Wer liefert dieses Teil? 15 Betriebe im Verzeichnis

Heinen & Hopman
NoneNetherlands
✓ autorisiert
Heinen & Hopman Marine Equipment (Shanghai)
NoneChina
✓ autorisiert
LeBlanc & Associates, LLC
Houma, United States
✓ autorisiert
Teknotherm Marine AS
NoneNorway
✓ autorisiert
A. Nobel en Zn. - Filtration & Separation B.V. (Headquarters)
NoneNetherlands
Dan Marine Shanghai Ltd.
NoneChina|Greece
Dingbro Ltd Industrial Filtration Division
NoneUnited Kingdom
Dolphin Marine Engineering & Trading Co., Ltd
China
El shaddai shipping
NoneTogo
GES SHIP
NoneTurkey|Georgia|Norway|Denmark|Finland|Italy|Kazakstan|Latvia|Portugal|Russian Federation|Spain|Azerbaijan|Turkmenistan|Egypt|Belgium|Malta|Libya
Galata Ship Supply Inc.
Turkey
HYDRUS ENGINEERING SA
Greece
Alle Betriebe für Heinen & Hopman ansehen →