"> J&E Hall International HallScrew Semi-hermetic Air-Cooled Ammonia Chiller
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
J&E Hall International

HallScrew Semi-hermetic Air-Cooled Ammonia Chiller

J&E Hall International HallScrew Semi-hermetic Air-Cooled Ammonia Chiller — Low-charge air-cooled ammonia chiller using HallScrew semi-hermetic single-screw compressors. Designed for cold store cooling, process cooling, and comfort cooling. Available in single or dual compressor configuration. Suitable for industrial and marine refrigeration applications..

J&E Hall International HallScrew Semi-hermetic Air-Cooled Ammonia Chiller

Inspector Detail

Common issues

  • Ammonia leakage at the compressor shaft seal, valves, or pipe joints
  • Screw compressor slide valve/capacity control sticking
  • Oil separator or oil return system fouling causing oil carryover from the compressor
  • Condenser fan motor or fan blade failure reducing head pressure control
  • Gasket or fitting degradation causing low-level ammonia odor/leaks
  • Compressor motor overheating from low refrigerant charge or a fouled condenser
  • Suction or discharge valve leakage reducing compressor capacity

Inspection checklist

  • Check for ammonia odor or leaks with an appropriate detector at joints, valves, and seals
  • Inspect the condenser coil/fins for fouling and clean as needed
  • Check oil level and oil pressure differential across the compressor
  • Verify high/low pressure and oil safety cutouts trip correctly
  • Check slide valve operation and capacity control response
  • Check refrigerant charge level via sight glass or level indicator
  • Inspect suction line insulation for condensation or ice buildup
  • Test the ammonia detection/alarm system
  • Check condenser fan motors for vibration or bearing noise

Service intervals

Oil change/analysis typically 4000-8000 hours or annually, per maker's schedule
Safety cutout (HP/LP/oil) testing per class requirement, typically annually
Condenser coil cleaning quarterly or per fouling condition
Ammonia detection system calibration per maker/class schedule, typically annually

Typical wear limits

Oil moisture/acid level monitor via oil analysis trend against the maker's limits rather than a fixed onboard reading
Refrigerant charge level maintain per the sight glass/level indicator range specified by the maker - do not top up without first tracing and repairing any leak

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Shaft seal kit for the screw compressor
  • Solenoid/expansion valve
  • Oil filter element
  • Refrigerant filter-drier
  • High/low pressure safety switch
  • Condenser fan motor
  • Refrigerant joint gasket/O-ring set

Safety

  • Ammonia is toxic and, in certain concentrations, flammable - full PPE (gas-tight goggles, gloves, escape breathing apparatus) is required for any refrigerant work
  • Confirm the ammonia detection and alarm system is operational before entering the compressor/chiller space
  • Refrigerant piping and vessels are under pressure - isolate and recover charge before opening
  • Screw compressor rotating parts and drive coupling guards must be fitted
  • Ensure adequate ventilation of the machinery space per class requirements for ammonia systems

Class survey

Ammonia refrigeration plant is subject to class rules specific to toxic/flammable refrigerants (detection, ventilation, machinery space arrangement) in addition to standard refrigeration machinery survey. Class checks leak detection function, pressure vessel/piping certification, and relief discharge arrangements at survey.

Components & Design

Component data being added…

Technical Data

cooling capacity kW high temp 350–960
cooling capacity kW medium temp 195–550
cooling capacity kW low temp 100–260
refrigerant NH3 (ammonia)
compressor HallScrew semi-hermetic single screw
temperature range cold store -18°C to +15°C
temperature range process -25°C to +7°C

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Check and clean refrigerant circuit: inspect for leaks (NH3 or HFC), verify refrigerant charge level, and test ammonia leak detection sensors (if fitted)

Check and clean refrigerant circuit: inspect for leaks (NH3 or HFC), verify refrigerant charge level, and test ammonia leak detection sensors (if fitted)

Inspect and service compressor: check oil level and oil pressure, replace oil filter, verify bearing temperatures and vibration levels against manufacturer limi

Inspect and service compressor: check oil level and oil pressure, replace oil filter, verify bearing temperatures and vibration levels against manufacturer limits

Clean heat exchangers: inspect and clean evaporator and condenser (water-side fouling, shell-and-tube or plate HX scaling; air-side coil cleaning for air-cooled

Clean heat exchangers: inspect and clean evaporator and condenser (water-side fouling, shell-and-tube or plate HX scaling; air-side coil cleaning for air-cooled units)

Verify shock-mount and structural integrity: inspect anti-vibration/shock mounts for wear or deterioration, check skid/base-frame fastenings and pipe flex conne

Verify shock-mount and structural integrity: inspect anti-vibration/shock mounts for wear or deterioration, check skid/base-frame fastenings and pipe flex connections (critical for naval shock ratings up to 30g)

Test safety and control systems: verify high-pressure and low-pressure cut-outs, flow switches, thermostatic controls, and SCADA/monitoring connectivity; test a

Test safety and control systems: verify high-pressure and low-pressure cut-outs, flow switches, thermostatic controls, and SCADA/monitoring connectivity; test ammonia/refrigerant alarms

Inspect electrical components: check terminal connections, contactor condition, motor insulation resistance (megger test), and rating of variable-frequency driv

Inspect electrical components: check terminal connections, contactor condition, motor insulation resistance (megger test), and rating of variable-frequency drives; confirm SOLAS low-smoke wiring integrity

Check glycol/brine secondary circuit: verify glycol concentration (freeze point), inhibitor levels, pH, and absence of corrosion or fouling in the secondary sid

Check glycol/brine secondary circuit: verify glycol concentration (freeze point), inhibitor levels, pH, and absence of corrosion or fouling in the secondary side; inspect pump seals and strainers

Review classification society documentation: confirm pressure vessel inspection records are current (LR or equivalent), update service logbook, and verify compl

Review classification society documentation: confirm pressure vessel inspection records are current (LR or equivalent), update service logbook, and verify compliance with applicable marine standards (SOLAS, class rules)

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet