EWWH-VZ

Daikin EWWH-VZ — Water-cooled inverter screw chiller with ultra-low GWP refrigerant for comfort, process and marine applications..

Components & Design

Component data being added…

Technical Data

cooling capacity kW 329–1540
refrigerant R-1234ze (GWP near 0)
compressor Inverter-driven single screw

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Inspect seawater/condenser water inlet strainer and heat exchanger tube bundle for biofouling, scale, and corrosion; clean per manufacturer interval

Inspect seawater/condenser water inlet strainer and heat exchanger tube bundle for biofouling, scale, and corrosion; clean per manufacturer interval

Check refrigerant charge, look for oil contamination, and verify absence of leaks at fittings, valve stems, and brazed joints using electronic leak detector

Check refrigerant charge, look for oil contamination, and verify absence of leaks at fittings, valve stems, and brazed joints using electronic leak detector

Verify operation of oil separator, oil reservoir level (critical for pitch/roll marine version), and oil heater function before startup

Verify operation of oil separator, oil reservoir level (critical for pitch/roll marine version), and oil heater function before startup

Inspect and test accelerometers (marine VZ units) that trigger EEXV control during vessel pitch/roll; confirm correct alarm and control response

Inspect and test accelerometers (marine VZ units) that trigger EEXV control during vessel pitch/roll; confirm correct alarm and control response

Check evaporator and condenser water flow rates, inlet/outlet temperatures, and pressure drops against design values; clean strainers

Check evaporator and condenser water flow rates, inlet/outlet temperatures, and pressure drops against design values; clean strainers

Test safety and control devices: high/low refrigerant pressure cutouts, chilled water flow switch, motor overload relays, and anti-freeze protection

Test safety and control devices: high/low refrigerant pressure cutouts, chilled water flow switch, motor overload relays, and anti-freeze protection

Inspect structural mounts, anti-vibration isolators, and pipe flexible connections for corrosion and mechanical integrity in the marine environment

Inspect structural mounts, anti-vibration isolators, and pipe flexible connections for corrosion and mechanical integrity in the marine environment

Verify electrical panel condition: check terminal tightness, insulation resistance, inverter/VFD drive status and fault logs, and confirm earthing/bonding to sh

Verify electrical panel condition: check terminal tightness, insulation resistance, inverter/VFD drive status and fault logs, and confirm earthing/bonding to ship's structure

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #152161 · ✓ still in production