Technical Data

cooling capacity kW 190-1100
absorbed power kW 27.8-161
refrigerant R134a
power supply 3x400/440V 50Hz
flow rate m3h 27.8-161
condenser flow m3h 14.5-82.4
dimensions m 3.20x1.00x1.66 to 4.30x1.60x2.25
weight kg 1960-6900
max current A 92-465

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Check compressor refrigerant charge level and type (R134a or R410a) - proper charging is critical for efficiency and performance

Check compressor refrigerant charge level and type (R134a or R410a) - proper charging is critical for efficiency and performance

Inspect compressor mounting and vibration isolation - ensure all fasteners are tight and rubber mounts are not deteriorated

Inspect compressor mounting and vibration isolation - ensure all fasteners are tight and rubber mounts are not deteriorated

Monitor compressor discharge temperature - excessive temperature may indicate insufficient oil return or overcharging

Monitor compressor discharge temperature - excessive temperature may indicate insufficient oil return or overcharging

Verify oil level and condition in semi-hermetic compressors - contaminated or low oil can cause bearing damage

Verify oil level and condition in semi-hermetic compressors - contaminated or low oil can cause bearing damage

Inspect suction and discharge lines for proper insulation - heat loss reduces efficiency and can cause liquid slugging

Inspect suction and discharge lines for proper insulation - heat loss reduces efficiency and can cause liquid slugging

Check condenser cooling water flow rate and temperature - blockages or inadequate cooling reduce efficiency

Check condenser cooling water flow rate and temperature - blockages or inadequate cooling reduce efficiency

Test capacity control system operation (25/50/75/100% modulation) - ensures proper load matching and efficiency

Test capacity control system operation (25/50/75/100% modulation) - ensures proper load matching and efficiency

Examine electrical connections and ground continuity - proper grounding prevents corrosion in marine environments

Examine electrical connections and ground continuity - proper grounding prevents corrosion in marine environments

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #151285 · ✓ still in production

Wer liefert dieses Teil? 5 Betriebe im Verzeichnis

LeBlanc & Associates, LLC
Houma, United States
✓ autorisiert
Dolphin Marine Engineering & Trading Co., Ltd
China
Galata Ship Supply Inc.
Turkey
HYDRUS ENGINEERING SA
Greece
Winkong Marine Engineering Co., Ltd.
China
Alle Betriebe für Heinen & Hopman ansehen →