Cummins Holset Turbochargers

HX20

Cummins Holset Turbochargers HX20 — Light-duty commercial diesel engines, up to 4L displacement.

Components & Design

Component data being added…

Technical Data

displacement range L up to 4

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Journal bearing bore inspection for wear marks and score damage; bore diameter must meet specifications or housing requires replacement

Journal bearing bore inspection for wear marks and score damage; bore diameter must meet specifications or housing requires replacement

Turbine and compressor wheel blade inspection for cracks, bends, deformation, or damage; replace if any defects found

Turbine and compressor wheel blade inspection for cracks, bends, deformation, or damage; replace if any defects found

Rotor assembly run-out and axial/radial clearances verification using dial gauges and vee blocks; clearances must meet published specifications

Rotor assembly run-out and axial/radial clearances verification using dial gauges and vee blocks; clearances must meet published specifications

Oil system quality and pressure verification: minimum 210 kPa at load, maximum 500 kPa operating (600 kPa at cold start); check for carbon buildup restricting r

Oil system quality and pressure verification: minimum 210 kPa at load, maximum 500 kPa operating (600 kPa at cold start); check for carbon buildup restricting rotation

Air intake and compressor housing cleanliness; inspect for debris, contamination, or air leak points; check compressor wheel for foreign object damage (FOD)

Air intake and compressor housing cleanliness; inspect for debris, contamination, or air leak points; check compressor wheel for foreign object damage (FOD)

Exhaust side and turbine housing inspection for cracks, heat damage, or thermal fatigue; verify seal integrity and gasket condition

Exhaust side and turbine housing inspection for cracks, heat damage, or thermal fatigue; verify seal integrity and gasket condition

Oil supply and drain line verification for blockages, contamination, or improper connection; confirm adequate oil cooling in bearing housing

Oil supply and drain line verification for blockages, contamination, or improper connection; confirm adequate oil cooling in bearing housing

Variable geometry vane (VGT) or wastegate actuator functionality testing; check for smooth operation and proper actuation response if applicable

Variable geometry vane (VGT) or wastegate actuator functionality testing; check for smooth operation and proper actuation response if applicable

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #150653 · ✓ still in production