Behrens VRF 9/350G — Vertical inline centrifugal pump - Main seawater cooling, LT fresh water.

Specifications

Technical data.

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Reference values — not verified
Pressure1.5-2.0 bar
Speed1780 rpm
Power85.7-94 kW

Source: zedmar.com · not checked against a manufacturer datasheet

Inspection

Inspector Detail

Common issues

  • Mechanical seal weeping or failure, often triggered by dry running or cavitation on start-up
  • Impeller erosion and pitting from cavitation, aggravated by seawater carrying sand or silt
  • Bearing wear or overheating from misalignment, or seawater ingress into the bearing housing after a seal failure
  • Casing wear ring clearance increasing over time, causing loss of head and capacity
  • Shaft sleeve corrosion at the seal faces in continuous seawater service
  • Coupling misalignment leading to vibration and premature bearing or seal failure
  • Suction strainer fouling causing cavitation and reduced flow
  • Motor overload from a partially blocked discharge or worn internal clearances forcing the pump off its curve

Inspection checklist

  • Check mechanical seal for leakage at the gland
  • Check bearing housing temperature and vibration levels
  • Compare discharge pressure and flow against the pump's baseline performance curve
  • Inspect suction strainer/sea chest for fouling
  • Check coupling alignment
  • Inspect casing wear rings and impeller clearances at overhaul
  • Check motor running current against nameplate rating
  • Listen for cavitation noise, especially at low suction head
  • Check foundation bolts and pipework supports for looseness or vibration marks

Service intervals

Mechanical seal inspectiontypically every 4,000-6,000 running hours or annually, whichever comes first - confirm against the maker's maintenance schedule
Bearing lubrication/grease renewaltypically every 4,000-8,000 running hours depending on bearing type and grease spec
Coupling alignment checkannually, and after any work disturbing pump or motor position
Suction strainer cleaningper operational schedule, more frequently in silty or biofouled water
Wear ring/impeller clearance checkat major overhaul, typically every 2-4 years of continuous service

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Casing wear ring radial clearancetypically 0.3-0.5 mm for centrifugal pumps in this capacity class - confirm against the maker's manual before condemning a ring
Shaft/bearing radial playrenewal is typically indicated once play exceeds roughly 0.05-0.10 mm above the as-new value - verify against maker tolerances

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Mechanical seal kit
  • Shaft sleeve
  • Bearing set (drive end/non-drive end)
  • Casing wear rings
  • Gasket and O-ring set
  • Coupling element/insert

Safety

  • Rotating shaft and coupling - guard must be fitted before running
  • Pressurized seawater system - isolate and vent before opening the casing
  • Electrical hazard at the motor terminal box - lock out/tag out before maintenance
  • Heavy components (motor, casing halves) - use proper lifting gear during overhaul

Class survey

As an essential seawater cooling pump, this unit typically falls under Continuous Survey of Machinery where the ship carries that notation; surveyors look for a satisfactory running/performance test, up-to-date seal and bearing maintenance records, and evidence that standby capacity is available

Estimated lifetime: No standard running-hour figure applies to a seawater centrifugal pump; service life is normally expressed in years (commonly 15-25 years) and is driven by seal and bearing renewal cycles and water quality rather than a fixed hour count

Need this part?

Request a quote for this model.

Free of charge — send us your request for Behrens equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Centrifugal Pump.

Other models of the same equipment type, Behrens first.

By manufacturer KSBDESMIGrundfosKawamotoShinkoINOXPACalpeda MarineTaiko KikaiSVANEHØJSulzerAllweilerIron PumpWärtsiläEbaraJohnson PumpAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Behrens models More like VRF 9/350G
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Behrens VRF 9/350G — a part, a service call, a second opinion. Are you Behrens? Claim this brand page.

Service engineer? Write the day report for this VRF 9/350G in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.