OceanSphere
Engines
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 1 verified suppliers & service companies for Sterling SIHI in the Maritime Network Find suppliers →
Sterling SIHI

UEA

Sterling SIHI UEA — Gas-handling centrifugal pump for LPG and marine liquid gas transhipment.

Components & Design

Component data being added…

Technical Data

Model Range UEA 5002 to UEA 10015
Capacity Up to 220 m³/h
Pressure Max 20 bar, casing up to 40-25 bar (sizes 8000/10000)
Temperature -40°C to +80°C
Speed Up to 3,600 rpm
Design Multistage with axial inlet NPSH inducer

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Mechanical seal leakage or degradation

Monitor seal flush flow rate and discharge temperature daily on critical pumps. Inspect visible signs of leakage around seal area. Replace seals at manufacturer-recommended intervals (typically 2,000-5,000 operating hours depending on application). Verify mechanical seal material compatibility with pumped liquid.

Coupling misalignment causing vibration and bearing wear

Measure coupling alignment using dial indicators or laser alignment tools to maintain within 0.1 mil/inch angular tolerance and 0.002 inch per inch axial tolerance. Check for parallel, angular, and axial misalignment. Verify alignment after any mechanical work or maintenance. Re-check monthly during operation.

Bearing failure due to misalignment, inadequate lubrication, or wear

Inspect bearing oil for water content and discoloration. Feel all bearing housings for excessive temperature (baseline + 10°C or more indicates problems). Check oil rings and filling ports. Verify lubrication grade matches OEM specification. Establish baseline vibration readings (horizontal, vertical, axial) at bearing locations; any increase >25% signals developing bearing issues.

Cavitation and impeller damage from low NPSH or suction-side restrictions

Verify positive suction head is sufficient (minimum recommended 0.5-1.5 m depending on pump model). Check suction strainers for blockage and clean as required. Monitor discharge pressure for fluctuations. Listen for cavitation noise (grinding/rattling sound). Inspect impeller for erosion/pitting during disassembly. Verify suction piping diameter and validate with NPSH calculations.

Vibration increase indicating imbalance, misalignment, or internal wear

Establish baseline vibration signature when pump is new or after overhaul. Measure at bearing housings in three axes (horizontal, vertical, axial). Monitor periodically using vibration analysis equipment. Alert threshold: any reading increase of 25% above baseline. Investigate root causes: imbalance, misalignment, bearing wear, cavitation, or loose mounting bolts. Recalibrate after repairs.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #149469 · ✓ still in production