Common failures & inspection points
Measure vibration at bearing housings using vibration sensors (typically at upper and lower bearing locations, on gear box, and at base). Standard operating level should be below 8 mm/s.
Monitor main bearing temperature via integrated temperature sensors on control panel. Compare against baseline and manufacturer limits. Automatic lubrication systems must be verified functional.
Visual inspection of bowl interior for scoring, wear patterns, or debris. Verify smooth rotation during start-up without grinding sounds. Check differential speed controller operation.
Inspect seal chambers for oil seepage. Verify seal flushing system operation. Check for product leakage at bowl discharge area and bearing housings.
Monitor motor current draw and vibration frequency spectrum via control panel. Verify VFD operation and roto-variator response. Check coupling condition between motor and gearbox.