Alfa Laval Aalborg

Aalborg EX

Alfa Laval Aalborg Aalborg EX — Waste heat recovery heater - Forced-circulation vertical heater for recovering heat from exhaust gases into closed-loop thermal oil systems.

Alfa Laval Aalborg Aalborg EX

Components & Design

Component data being added…

Technical Data

Type Exhaust gas economizer for thermal fluid heating
Capacity Range 100-5,000 kW
Design Temperature 280 degrees Celsius
Heat Transfer Medium Mineral oils or water
Configuration Forced circulation vertical with up to nine coils of bare tubes
Features Customizable bypass damper; soot-cleaning water spray nozzles; firefighting water-spray system

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Tube coil and combustion chamber inspection

Visual examination of heat exchanger tubes, double coil bare tube configuration, and combustion chamber for scale deposits, corrosion, and erosion. Access plates and manholes must be removed for thorough inspection.

Thermal fluid chemistry and degradation

Verification of thermal fluid properties (viscosity index >100, flash point COC >180°C, film temperature capability ≥340°C) and check for oxidation/degradation indicating fluid change requirement

Pressure relief and safety valve function

Testing of safety valves (main system valve at 10 bar(g), expansion tank valve at 4 bar(g), minimum flow control at 2.5 bar(g)) and documentation of pressure test results per ASME/PED standards

Refractory condition and insulation integrity

Examination of refractory lining for cracks, spalling, or deterioration; inspection of external insulation jacket for damage; thermal camera inspection for heat loss anomalies

Burner and combustion efficiency

Inspection of burner assembly (monoblock pressure jet or rotary cup), flue gas analysis, combustion chamber temperature verification, and soot accumulation assessment. For EX models, soot-cleaning nozzle functionality check

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #149259 · ✓ still in production