Hoshizaki (Gram)

MARINE COMPACT F 610 RH 60 HZ LM 5M

Hoshizaki (Gram) MARINE COMPACT F 610 RH 60 HZ LM 5M — Marine/Offshore Galley - Freezer for vessel kitchens.

Components & Design

Component data being added…

Technical Data

Type Freezer with solid door
Dimensions (W×D×H) 695×868×2005 mm
Net Volume 419 liters
Gross Volume 583 liters
Temperature Range -25°C to -5°C
Power Supply 230V, 60Hz
Refrigerant R452a (0.22 kg)
Door Right-hinged door with lock
Shelf Configuration 5 stainless marine shelves (2/1 GN deep)
Features Stainless steel construction, marine legs (not factory fitted), dedicated locking marine handle, sea-stability design
Item Number 866100281

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Door Gasket/Seal Degradation

Dollar bill test - close door on currency and attempt to pull it out around entire perimeter. Check for cracks, tears, brittleness, excessive stickiness. Verify seal remains soft and pliable; inspect corners and hinge side under stress.

Temperature Stability & Performance

Monitor internal temperature with separate thermometer daily. Verify refrigerator maintains 37-40°F (2-4°C), freezer maintains -4°F (-20°C). Check for temperature fluctuations, frost buildup, or uneven cooling across all shelves.

Compressor Vibration & Noise

Listen for unusual rattling, grinding, or squealing. Inspect for excessive vibration in mounting brackets and refrigerant lines. Check for signs of metal fatigue, loose fasteners, or thermal expansion damage. Verify no salt/corrosion buildup.

Marine Shelf Fixation & Sea Stability

Verify all shelves are properly fixed to guide pins and supports with no play or movement when vessel rocks. Inspect guide pins for wear, bent clips, or misalignment. Confirm shelves remain secure under simulated heavy sea conditions.

Refrigerant & Pressure System Integrity

Check for oil leaks around compressor connections, condenser coils, and refrigerant lines. Verify refrigerant levels per nameplate specs. Inspect for frost accumulation on suction line indicating low charge. Test pressure readings with gauges; document baseline values.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #149205 · ✓ still in production