Survitec PP6P — ABC powder stored pressure fire extinguisher for marine and industrial portable use.

Components & Design

Component data being added…

Technical Data

Capacity 6 kg
Type Stored Pressure
Extinguishing Agent Mono-ammonium phosphate (MAP)
Propellant Nitrogen stored pressure
Material 2 mm steel, shot blasted, polyester coated
Hose Long, non-kinking with tap control
Pressure Indicator Monitors pressure over time
Testing Helium test for leak-tightness
Standards EN 3-7, MED 96/98 EC
Electrical Safety Up to 35 kV

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Cylinder integrity and structural damage

Visual inspection for dents, cracks, corrosion, or rust on the 2mm steel cylinder; check polyester coating condition for damage or peeling that could expose metal to corrosion

Pressure gauge/indicator accuracy and function

For stored pressure models (PP2P, PP6P, PP9P, CO2): verify pressure indicator needle position is in correct operating range; test gauge responsiveness; for cartridge models, verify cartridge is properly installed and not corroded

Safety pin and tamper-evident device integrity

Verify anti-rust safety pin is present, intact, and can be removed/reinserted; check lead seal or tamper seal for signs of tampering or removal; ensure safety pin is not corroded or stuck

Nozzle/spray mechanism functionality and obstruction

For models with discharge nozzles (water, foam, powder cartridge, fat fire): test spray discharge ability without releasing agent; verify nozzle is not clogged or obstructed; check hose for kinks, cracks, or brittleness; inspect rotating coupling for corrosion

Mounting bracket and attachment security

Where applicable (models with brackets): verify bracket is securely attached to extinguisher; check all fasteners are tight and not corroded; ensure strap mechanisms function correctly; confirm bracket mounting surface on wall/vessel is secure

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #149098 · ✓ still in production