OceanSphere
Engines
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 36 verified suppliers & service companies for Tyco in the Maritime Network Find suppliers →
Tyco

MRA-1 Manual Reset Actuator

Tyco MRA-1 Manual Reset Actuator — Manual Reset Mechanism for DV-5A Deluge/Preaction Valves.

Components & Design

Component data being added…

Technical Data

Pressure Rating 300 psi (20.7 bar)
Material Bronze body construction
Mechanism Hydraulic latch maintains tripped position
Feature External reset restores valve after system shutdown
Actuation Triggered via solenoid valve, DP-1, or MC-1 control station

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Diaphragm Integrity and Leakage

Inspect for water or air leakage from bonnet cover and outlet drain; verify no external moisture on diaphragm chamber; perform annual full trip test to verify diaphragm response and proper valve opening

Strainer and Filter Blockage

Clean strainer in diaphragm chamber supply control valve; inspect for sediment, corrosion debris, or mineral deposits; perform internal inspection of strainers every 5 years per NFPA 25; replace if significant blockage detected

Pilot Line Pressure and Air Supply

Verify dry pilot line air pressure maintained at design pressure (typically 40-50 psi); check for air leaks at connections; ensure air drier functioning and dew point below lowest ambient temperature; test pressure gauge reading weekly

Nozzle and Sprinkler Condition

Inspect all deluge nozzles/sprinklers for corrosion, mechanical damage, or buildup; verify proper orientation and alignment; check for blockage or paint over orifices; ensure DN-5 duct nozzles maintain HALAR coating integrity

Control Valve Assembly Condition

Check for external corrosion on valve body, actuators, and piping; verify bonnet bolts are tight; inspect manual reset actuator (MRA-1) for damage; ensure dry pilot actuators (DP-1/DP-2) have no water/air leakage at drain outlet

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148836 · ✓ still in production

Wer liefert dieses Teil? 35 Betriebe im Verzeichnis · 49 aus Herstellerlisten

Euploia Drydocks & Services
Greece
Actuation Valve & Control Ltd
Liverpool, United Kingdom
Acutus AS
Halden, Norway
Al Bilad Riyadh Saudi Arabia
Saudi Arabia
Arcolec
La Perouse, Australia
Bistek Marine Electronics Ltd
Bistek Marine Electronics Ltd
Bronia Gmbh
Germany
Bronia Gmbh
Germany
Bronia Gmbh
Germany
Bronia Gmbh
Germany
Control Equipment Ltd
United Kingdom
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Johnson Controls S.p.A. - Global Marine & Navy Italy · ItalyJohnson Controls S.p.A. - Global Marine & Navy Italy · ItalyA.S. Moloobhoy FZCO, UAE · United Arab EmiratesA.S. Moloobhoy Pvt. Ltd. · IndiaA.S. Moloobhoy Pvt. Ltd. · IndiaA.S. Moloobhoy Pvt. Ltd. · IndiaA.S. Moloobhoy Pvt. Ltd. · IndiaBass Offshore Limited · United KingdomBrown Technologies Pte Ltd · SingaporeCrucible Engineering · United StatesCrucible Engineering · United StatesDräger Marine & Offshore B.V. · Netherlands
Alle Betriebe für Tyco ansehen →