Ultra Fog

202 Open Nozzle

Ultra Fog 202 Open Nozzle — Fire suppression with intelligent activation in machinery spaces and engine rooms.

Inspector Detail

Common issues

  • Nozzle orifice blockage or corrosion from stagnant water or scale in the pipework
  • Section (zone) valve or solenoid failing to open on demand
  • High-pressure pipe or fitting leakage at connections
  • Pressure/flow switch giving false signals
  • Corrosion of the nozzle body in an engine room or salt-laden environment
  • Faulty detection-to-release interface causing missed or accidental activation

Inspection checklist

  • Visual inspection of nozzles for corrosion, blockage or paint overspray
  • Inspect high-pressure pipework and fittings for leaks
  • Function test of section (zone) valves
  • Pump unit start and pressure build-up test
  • Functional test of the detection-to-release interface per zone
  • Check accumulator/pressure vessel condition if fitted
  • Check nozzle deflector plate condition and correct orientation

Service intervals

Nozzle visual inspection quarterly to annual per the ship's PMS
Full system/discharge function test annual, typically as a partial/test-zone discharge per maker and class
Pump unit test run monthly
High-pressure pipe pressure test per class survey interval, commonly around every 5 years

Typical wear limits

Nozzle orifice condition any visible pitting, blockage or deformation of the orifice is normally cause for replacement rather than continued service at this pressure class - confirm against Ultra Fog's maintenance manual

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Replacement open nozzles
  • Section (zone) valves
  • High-pressure fittings and O-rings
  • Pump seal kit
  • Pressure/flow switches

Safety

  • Stored high-pressure water (100 bar) - injury risk from accidental discharge or line rupture
  • Isolate the relevant section before working on any nozzle or valve
  • Electrical isolation of the pump unit and detection interface during maintenance
  • Slip hazard from test discharge water in the machinery space

Class survey

Fixed water mist fire suppression in machinery spaces is SOLAS Ch.II-2 equipment; class wants annual function/discharge test records, pump capacity and pressure test results, and confirmation the system remains on the approved type list for the protected space.

Estimated lifetime: Not rated in running hours; nozzles and valves are serviced on a calendar/test-cycle basis, with replacement driven by corrosion or blockage condition rather than hours run.

Components & Design

Component data being added…

Technical Data

Activation Type Intelligent (open nozzle, normally open)
Working Pressure 100 bar
Mounting Star lock for easy mounting, M20 threaded body with optional nut
Coverage Area Up to 48 square meters per nozzle

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Nozzle clogging and blockade from mineral deposits, biofilm, or sediment accumulation preventing proper water mist generation

Visually inspect nozzles for blockages; use patented Ultra Fog Nozzle Test Tool to verify piston function without breaking glass bulbs; conduct laboratory testing of nozzles after 10 years service and every 5 years thereafter

Pump performance degradation including abnormal noise, vibration, and reduced flow capacity indicating internal wear or cavitation damage

Measure discharge pressure against pump characteristic curve; check for unusual operating noise or vibration; verify flow rate capacity (35-50 L/min for P35 model); monitor motor current draw for erratic startup cycles indicating filter blockage

Nitrogen pre-charge loss in accumulator unit reducing system pressure stability and emergency discharge capability during fire event

Verify nitrogen pre-pressure setting (typically 90% of operating pressure for 100 bar systems); test accumulator pressure switch alarm function; inspect for visible corrosion, cracks, or leakage in accumulator body; calibrate all pressure gauges annually

Filter clogging at inlet (25µm stage) or discharge (100µm stage) causing pump short-cycling, pressure loss, or nozzle blockade formation

Document filter cleanliness condition; measure pressure differential across filters (high differential indicates clogging); perform visual inspection of inlet and outlet filter elements; clean or replace filters after system operation or annually minimum; verify dual 25µm tank filters are present and functional

Piping corrosion, sediment deposits, and internal rust scale generating blockages in distribution network or damaging pressure seals

Pressure test entire piping network at 1.5x maximum working pressure (150 bar minimum for 100 bar systems); inspect water supply tank interior annually for sediment/rust accumulation; flush system annually; drain and refill water tank yearly; verify air passage from nozzles is unobstructed

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148712 · ✓ still in production

Wer liefert dieses Teil? 2 Betriebe im Verzeichnis · 1 aus Herstellerlisten

Marinefire S.r.l.
Pieve A Elici, Italy
SAILTEC GmbH
Schenefeld, Germany
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Ultrafog Service S.A.R.L. · Monaco
Alle Betriebe für Ultra Fog ansehen →