"> Danfoss APP W 8.2
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 33 verified suppliers & service companies for Danfoss in the Maritime Network Find suppliers →
Danfoss

APP W 8.2

Danfoss APP W 8.2 — Zero Liquid Discharge (ZLD) / Minimal Liquid Discharge (MLD) Reverse Osmosis.

Components & Design

Component data being added…

Technical Data

Flow Range 8.2 m³/h (36.1 gpm)
Max Pressure 120 bar (1,740 psi)
Speed Range 700-1,200 rpm
Design Axial piston, oil-free, Duplex/Super Duplex stainless steel

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Feed Water Silt Density Index (SDI) Exceeds 3.0

Measure SDI before RO membrane inlet every 4 weeks using standard SDI test kit (0.45 µm filter, 15 minutes). SDI must remain below 3.0. If exceeding 3.0, pretreatment (multimedia filter, carbon filter, cartridge filter) requires backwashing and cartridge replacement

Membrane Fouling Detection - Differential Pressure Rise or Permeate Flow Decline

Monthly baseline pressure differential monitoring across membrane stages. A sudden spike in differential pressure (> 10% increase from baseline) indicates fouling. Visual inspection for yellow slime (biofouling) or white crystals (scaling). Inspect feed spacer geometry and membrane autopsy if fouling suspected

Pump Pressure and Performance Degradation

Verify APP/PAH pump discharge pressure at standard flow rates weekly. Compare with baseline. Monitor power consumption (kW input). Check for cavitation noise or abnormal vibration. Verify pump inlet pressure 0.5-5 bar (7-72 psi). Inspect for seal leaks and corrosion on stainless steel surfaces

Energy Recovery Device (iSave/MPE) Efficiency Loss or Biofilm Fouling

Monitor ERD inlet/outlet pressures and flows monthly. Compare energy recovery efficiency to baseline (typically 92%). Inspect for scaling/fouling by measuring pressure drop across ERD. Visual inspection of high-pressure spacer for biofilm buildup. For MPE 70, verify motor rotation speed (650-875 rpm) and electrical current

Cartridge Filter Clogging and Breakthrough

Monitor prefilter differential pressure weekly (must stay below 1.5 bar; replace when reaching limit). Inspect cartridge visual condition (melt blown polypropylene for 3 µm stage, 10 µ absolute for main stage). Replace cartridges immediately if pressure differential exceeds maximum or after 12 months operation. Verify Beta 5000 rating for main filters (10 µ absolute minimum)

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148604 · ✓ still in production