PROTEGO

UB-SF-G

PROTEGO UB-SF-G — Tank Pressure/Vacuum Diaphragm Valve - Gas-Specific.

Components & Design

Component data being added…

Technical Data

Design Gas-specific flame arrestor variant
Flame Arrester Static and dynamic protection
Pressure Range +3.5 to +140 mbar
Vacuum Range -3.5 to -35 mbar
Material Diaphragm design for problematic products

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Valve Seat Erosion and Corrosion

Visually inspect stainless steel valve seats for signs of erosion, corrosion, pitting, or chemical attack. Check sealing surfaces under magnification (20x) for any visible damage, scratches, or grooves that could compromise the seal.

Valve Pallet or Diaphragm Condition

Examine weight-loaded or spring-loaded valve pallets for cracks, permanent deformation, wear patterns, or loss of sealing integrity. For diaphragm-type valves (UB-SF series), check for tears, holes, or loss of elasticity in the FEP diaphragm material.

Flame Arrester Element Clogging or Blockage

For flame arrester-equipped models (VD-SV-EB, PV-EB, UB-SF series), inspect the FLAMEFILTER® element for deposits, corrosion, or particulate clogging. Pressure drop testing or visual inspection of element surfaces is required; recommend cleaning or replacement if >25% blockage detected.

Spring Tension Loss (Spring-Loaded Variants)

For -F model variants (DZ/T-F, DZ/E-F, DZ/EA-F, DV/ZT-F) with spring loading, verify spring force using calibrated testing equipment. Springs should return to original height without permanent set. Check for corrosion, stress cracks, or fatigue damage on spring surfaces.

Condensate Drainage System Obstruction

Verify automatic condensate drainage is functioning on all models. Inspect drain holes and pathways for ice blockage, mineral deposits, or organic fouling. Ensure drain tubes are clear and properly positioned; test drainage with small water injection at operating temperature.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148464 · ✓ still in production