Pres-Vac Engineering

VOCON Vapor Control System

Pres-Vac Engineering VOCON Vapor Control System — Automated vapor recovery and emission control system for loading/discharge monitoring and documentation.

Components & Design

Component data being added…

Technical Data

Function Remote-controlled vapor release with constant pressure
Capacity Range 2,400-26,000 Nm³/h
Control HMI touch screen, automatic/manual modes
Monitoring Pressure transmitter on IG main line
Standards IMO MSC/Circ. 680, MEPC.185(59), API 2000

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Pressure disc wear and deformation from repeated opening/closing cycles

Visual inspection of disc surface for pitting, cracks, scoring, and deformation; measure disc thickness and compare to original specifications; test disc opening pressure with calibrated pressure gauge

Seal degradation and leakage due to cargo contact and pressure cycling

Check neoprene or resilient seals for cracking, compression set, extrusion, or color change; perform soap bubble test for external leakage; measure leakage rate if equipped with test ports; inspect seat surface for erosion

Flame screen clogging and oil/sludge accumulation blocking gas flow

Visually inspect flame screen for oil mist, sludge, or particulate blockage; measure pressure drop across screen with manometer; remove screen element if accessible and clean or replace AISI 316L stainless steel screen; verify minimum clearance

Valve spring relaxation and loss of set pressure over time

Test pressure settings with calibrated relief valve test rig; compare opening and closing pressures to documented set points; inspect spring for corrosion, fatigue marks, or permanent deformation; replace spring assembly if pressure drift exceeds ±5% tolerance

Magnetic control circuit failure in Vacuum-M and DHM valves causing loss of valve response

Test magnetic actuation with hall effect sensor or magnetic flux meter; verify smooth valve movement through manual lift tests; check for debris or ferrous particle accumulation near magnet assembly; test electrical continuity if electromagnetically actuated variant

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148427 · ✓ still in production