Bloksma (Kelvion Machine Cooling) V-Type Oil & Water Heater — Heating in diesel engines, compressors, and hydraulic systems.

Components & Design

Component data being added…

Technical Data

Standard Shell Diameters V11, V16, V20, V22, V27, V32 (up to 320 mm)
Max Design Pressure 32 bar
Max Design Temperature 300°C
Tube Bundle Removable U-bends allowing free thermal expansion
Tube Material Seamless drawn St. 35.8 tubes with seal welding for thermal oil
Compliance All major marine classification societies and CE certified

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Corrosion of tube bundle and seawater-wetted components

Visual inspection of sacrificial anodes for depletion; check for galvanic corrosion on phenolic coating on tubes; verify cathodic protection system effectiveness (ICAF system status if equipped)

Biofouling and seawater blockage reducing heat transfer performance

Remove header/water box for visual inspection of tube bundle exterior; check for biological growth and sediment accumulation; measure pressure drop across cooler as fouling indicator; plan chemical or mechanical cleaning as needed

O-ring seal degradation and circuit intermixing risk

Inspect double O-rings on both sides for cracks, compression set, or extrusion; verify water box gasket condition; test for leakage between circuits (shell-side and tube-side isolation); check for discoloration or weeping at seal points

Tube side and shell side deposits limiting flow and heat transfer

Inspect tube interior for scale, rust, or oil sludge buildup; verify shell-side for sediment and scale accumulation; clean tubes chemically or mechanically per maintenance schedule; verify no internal blockages in water passages

Tube bundle structural integrity and mechanical vibration damage

Check for dents, cracks, or corrosion perforation in tube walls using visual inspection and leak testing; verify baffle spacing and tube support condition; confirm U-bend tube integrity in V-type heaters; inspect for loose or missing components

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #148368 · ✓ still in production