OceanSphere
Engines
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 1 verified suppliers & service companies for Bornemann (ITT Bornemann) in the Maritime Network Find suppliers →
Bornemann (ITT Bornemann)

EL-Series (Close-coupled design)

Bornemann (ITT Bornemann) EL-Series (Close-coupled design) — Compact heating oil, fuel transfer, industrial applications.

Components & Design

Component data being added…

Technical Data

Type Eccentric screw (progressive cavity), close-coupled
Capacity Up to 350 GPM (1.3 m³/h+)
Pressure Up to 180 psi (12 bar)
Temperature Up to 356°F (180°C)
Viscosity Up to 1,000,000 cSt

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Pump cavitation and suction performance degradation

Verify NPSH available exceeds pump NPSH required (typically 1.5-4m for Bornemann pumps); inspect suction line for blockages, check fuel tank level, confirm no air leaks in inlet lines

Mechanical seal failure and fuel leakage

Visually inspect mechanical seal housing for external leaks; monitor seal cavity temperature; confirm proper seal material selection for fuel type (API-682 compliance); check seal lubrication reservoir level

Bearing wear and shaft misalignment

Monitor pump vibration and temperature at bearing housings; check shaft alignment with dial indicator (TIR tolerance typically <0.05mm); inspect bearing lubrication (oil level and condition) every 500-1000 hours

Rotor/stator degradation in progressive cavity pumps (EH, E2H, ES series)

Measure discharge pressure drop vs. specification; inspect rotor surface for scoring or wear (endoscopy if possible); verify stator elastomer material compatibility with fuel type; replace rotor/stator assembly when wear exceeds 10% of design tolerance

Fuel contamination and strainer blockage

Inspect inlet strainer/filter mesh condition monthly; measure pressure drop across strainer; verify fuel cleanliness per ISO 4406 code (recommend <18/16/13 for fuel pumps); change strainer element when pressure drop exceeds manufacturer specification (typically 0.3-0.5 bar)

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #147856 · ✓ still in production

Wer liefert dieses Teil? 13 Betriebe im Verzeichnis · 4 aus Herstellerlisten

Fluid Global Solutions S.r.l.
Arcola, Italy
Hamburg FactorShip GmbH
Haselau, Germany
Japan Marine (S) Pte Ltd
Singapore, Singapore
Jon Heinr Bornemann GmbH
Germany
Liberty Marine Services, Inc.
Jacksonville, United States
MEYER RE GmbH
Papenburg, Germany
Mares Shipping GmbH
Hamburg, Germany
Marine Technic A/S
Naestved, Denmark
PG Flow Solutions AS
Sande i Vestfold, Norway
Roodhart Marine & Offshore Services
Rotterdam, Netherlands
Shiptec AG
Luzern, Switzerland
TMS - Hamburg Technical Marine Services GmbH
Heidgraben, Germany
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Freudenberg Technical Supply (Spares & Service) · GermanyNAVSUPPLY Ship Chandler 4 All Needs · BrazilSAACKE USA, Inc. · United StatesSudoservice GmbH · Germany
Alle Betriebe für Bornemann (ITT Bornemann) ansehen →