Library› Engine Room› Oily Water & Waste Systems› Sewage Treatment Plant› Hamworthy/Wartsila ST6A

ST6A

Sewage Treatment Plant · Oily Water & Waste Systems

Technical data from manufacturer or class sources · not yet verified by a person

Hamworthy/Wartsila ST6A — Medium sewage treatment for marine vessels and small offshore platforms.

Specifications

Technical data.

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Reference values — not verified
BOD Loading6.00 kg/day maximum

Source: dokumen.tips · not checked against a manufacturer datasheet

Inspection

Inspector Detail

Common issues

  • Aeration blower failure or reduced air delivery, causing incomplete biological treatment
  • Disinfection unit (chlorinator/electrolytic cell) fouling or electrode wear
  • Discolored or odorous effluent from insufficient retention time or a blower malfunction
  • Level sensor/float switch fouling causing pump short-cycling or tank overflow
  • Macerator or inlet screen blockage
  • Air diffuser fouling reducing oxygen transfer
  • Discharge/transfer pump seal wear or clogging with wipes/rags

Inspection checklist

  • Check aeration blower operation and air pressure/flow to the diffusers
  • Assess discharge water clarity and odor as a rough process indicator
  • Test the disinfection unit output where fitted
  • Check level switches and high-level/pump-failure alarms
  • Inspect and clean the macerator and inlet screen
  • Confirm the sample point is accessible for BOD/TSS testing
  • Check discharge valve interlocks that prevent discharge in restricted areas per MARPOL Annex IV
  • Inspect the tank interior for solids buildup at dry-docking or other opportunity

Service intervals

Blower filter/oil checkper manufacturer, typically every 500-1000 running hours
Diffuser cleaning/inspectionannually or when air distribution becomes uneven
Disinfection electrode/cell cleaningquarterly or per manufacturer
Macerator blade inspectionevery 3-6 months depending on usage
Full internal tank inspectionat dry-docking or per class interval
Effluent quality testingper flag state/MARPOL Annex IV requirement

Typical wear limits

Effluent quality (BOD/TSS/coliform)must meet the standard in the plant's own type approval certificate (e.g. IMO Res. MEPC.227(64)) rather than a generic figure
Diffuser air distributioneven bubbling across the diffuser bed - an uneven pattern indicates fouling or blockage needing cleaning

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Aeration blower belt/filter set
  • Air diffuser membranes
  • Level float switches
  • Macerator cutting blades
  • Discharge pump seal kit
  • Disinfection electrode, where fitted

Safety

  • Confined space entry hazard for internal tank inspection - test the atmosphere and follow the enclosed space entry procedure
  • Biological/pathogen exposure when handling sludge or effluent - PPE and hygiene required
  • Electrical hazard around blower and pump motors in a wet environment
  • MARPOL Annex IV restricts discharge distances/areas - do not discharge unless the plant is confirmed operating correctly

Class survey

The plant is subject to MARPOL Annex IV survey requirements and IOPP/Sewage certificate renewal. Class checks the type approval certificate validity, effluent sampling where required, and correct function of any discharge valve interlocks/logging.

Estimated lifetime: Typical service life is 15-20 years for the tank and structural components; blowers, pumps and electrical/electronic controls are usually replaced or overhauled within 8-12 years.

Need this part?

Request a quote for this model.

Free of charge — send us your request for Hamworthy/Wartsila equipment. Our team checks it and replies by e-mail.

Makers and authorised dealers rarely quote marine equipment without the vessel. With these details we can check availability and prices faster; without them we may have to ask first, which can cost a few days. If you cannot share the vessel, a photo of the equipment’s rating plate does the same job — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Sewage Treatment Plant.

Other models of the same equipment type, Hamworthy/Wartsila first.

By manufacturer EvacWärtsiläACO MarineTecnicomarJowaHamannVictor MarineScience Nature Technology (SNT)DetegasaDVZHanla IMSScienco/FAST, Bio-Microbics, Inc.GERTSEN & OLUFSENRWOGROCOAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Hamworthy/Wartsila models More like ST6A
Would you like to know more?

A person reads every request and replies by e-mail.

Tell us what you need for this Hamworthy/Wartsila ST6A — a part, a service call, a second opinion. Are you Hamworthy/Wartsila? Claim this brand page.

Service engineer? Write the day report for this ST6A in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Three things people ask first.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.