GEA

BilgeMaster-E 2500

GEA BilgeMaster-E 2500 — Bilge water treatment, legacy model, 15ppm capable.

Components & Design

Component data being added…

Technical Data

Capacity 2,500 l/h
Series E Series (400-5000 l/h range)
Oil Content Performance <15ppm without chemicals and filter, <5ppm with filter
Technology Centrifugal separation, no chemical additives required
Design Compact, automated cleaning

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Oil content exceeding discharge limit (>15ppm)

Verify oil content monitor (OCM/15ppm bilge alarm) reading and ensure overboard discharge valve is closed when threshold exceeded. Check integrated data recorder logs for discharge violations during previous 18 months. Verify alarm activation within 5 seconds and auto-stop device activation within 20 seconds.

Sampling point contamination or improper installation

Inspect sampling point location in vertical section of water effluent piping as close as practicable to separator outlet. Verify sample integrity (no floating oil layer), homogeneous mixture, and proper connection to oil content monitor. Ensure no bypass of OWS system and re-circulation facilities adjacent to overboard outlet.

Separator maintenance overdue or service interval exceeded

Confirm service interval tracking (16,000 operating hours for current models, 8,000 hours for legacy models). Verify maintenance records completion, including feed pump condition, automatic filter status, preheater function, bowl cleanliness, and oil monitor calibration. Check separator performance log for any efficiency degradation.

Oil monitor calibration accuracy loss or seal tampering

Verify 15ppm oil monitor calibration certificate and date of last calibration check (not exceeding 5 years from commissioning or manufacturer-specified interval). Inspect seal integrity on monitor access points. Confirm monitor cannot be accessed for cleaning or zeroing without breaking seal. Test alarm response with clean water to verify activation.

System bypass or incomplete separation during operation

Inspect modular unit assembly (feed pump/preheater and separator units) for physical disconnection or valve bypass. Verify all key components installed: feed pump operational, automatic filter unblocked, preheater maintaining fluid temperature (60-85°C per model), separator bowl for cracks/erosion, and control panel displaying no fault codes. Check return piping configuration to prevent by-pass.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #147358 · ✓ still in production