SJ100G / SJ100GH
Samgong Co., Ltd. SJ100G / SJ100GH — High-Capacity Fuel & Oil Purification.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Common failures & inspection points
Visual inspection for cracks, corrosion, erosion; verify bowl nut tightness, check tally mark alignment; apply back pressure monitoring to detect seal leakage
Monitor pressure differential at inlet vs. outlet (alarm if <0.01 MPa deviation); confirm back pressure maintains 0.15 MPa; activate leakage alarm at 0.12 MPa threshold
Monitor water detector via pressure sensor in circulation line; check alarm trigger activation when water content exceeds threshold; verify sludge discharge mechanism responds to water detection signal
Measure vibration at point A of purifier housing; stop unit if vibration exceeds 100 μm (peak-to-peak) at rated speed; inspect for installation issues or internal imbalance
Document pressure sensor replacement schedule; verify Multi-Monitor indicators for Leakage Monitor, Discharge Detector, Water Detector functionality; replace all sensors after 36 months operation
Type-general inspection and maintenance points for this equipment category — not model-specific.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.