Common failures & inspection points
Perform dye penetrant inspection (Dye Penetrant Inspection) per GEA standards to detect cracks and corrosion damage
Measure wall thickness reduction; document pitting and cracks (without risk of damage propagation)
Bowl and centrifugal pump components, product-dependent, inspect for corrosion and erosion; after 8,000–16,000 operating hours (maximum 2 years)
Validate water level sensor function; test automatic sludge discharge function; inspect pressure transducer and control unit for wear
Inspect tooth coupling and flat belt for wear and contamination; check bearing grease condition; lubricate crankshaft bearing