Sperre

XW200

Sperre XW200 — Starting air (high pressure) marine compressor, water-cooled, X-Range.

Components & Design

Component data being added…

Technical Data

Type Two-cylinder two-stage water-cooled X-Range compressor
Cooling Fresh water cooled
Pressure 30 bar maximum
Capacity @ 50Hz 200 m³/h
Capacity @ 60Hz 240 m³/h
Application Marine starting air system

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Oil level and quality degradation

Visual inspection of oil through sight glass monthly; check for discoloration, sludge, water contamination; replace per manufacturer schedule (typically 500-1000 operating hours)

Delivery pressure and temperature deviations

Record operating pressures and discharge temperatures daily; verify safety valve opens at correct pressure setting (typically 35-40 bar for marine units); ensure outlet air temperature stays within 10-30°C above ambient

Air and water leaks in connections

Visual inspection of all pneumatic hoses, fittings, and water cooling lines weekly for moisture, salt corrosion, or seepage; apply soapy water test to detect micro-leaks; inspect for salt crystallization typical of marine environment

Abnormal vibration and mechanical wear

Listen for unusual bearing noise or grinding sounds during operation; measure vibration levels (marine units typically max 40 mm/s RMS); inspect valve plates, piston rings, and cylinder walls for wear; perform visual exterior corrosion assessment

Cooling system efficiency and saltwater corrosion

For water-cooled units: verify cooling water pressure (0.5-3.0 bar typical); check for salt deposits or algae in cooling passages; ensure heat exchanger not fouled; inspect cooling water intake filters monthly; verify outlet temperature within specification

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet