Hyundai-Atlas

MAXI 50SL-1

Hyundai-Atlas MAXI 50SL-1 — Sludge & solid waste incinerator.

Components & Design

Component data being added…

Technical Data

Thermal capacity 372 kW (320,000 kcal/h)
Solid waste capacity 100 kg/h
Liquid waste capacity 38 kg/h
Flue gas temperature 350 degrees C

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Combustion chamber flue gas outlet temperature below operating minimum

Verify temperature monitoring system displays 850 degrees C minimum for continuous feed (600-850 degrees C for batch startup). Check thermocouple calibration and temperature recording instruments. Inspect documentation of temperature logs from operational records.

Missing or invalid Type Approval Certificate for shipboard incinerator

Request Type Approval Certificate issued by recognized classification society (DNV, USCG, ABS, LRS, GL, RMRS). Verify certificate includes IMO MEPC 244(66) or MEPC 76(40) compliance. Check certificate validity period (5-year renewal requirement). Compare incinerator model on vessel with certified model on certificate.

Prohibited waste types being incinerated

Inspect waste segregation procedures and crew training records. Check incinerator operational manual for prohibited materials list. Verify crew training certificates for authorized operators. Review waste records to ensure no PCBs, cargo residues (Annex I/II/III), heavy metal contamination, halogenated petroleum products, sewage sludge not generated onboard, or EGCS residues are burned.

Incinerator safety interlocks and flame detection system malfunctioning

Test flame detector sensors for proper ignition detection. Verify high-temperature alarms trigger at design limits. Inspect pressure relief valves for operability. Check primary burner interlock prevents sludge feeding if main burner not ignited. Verify equipment maintenance log shows periodic testing of safety devices.

Incomplete or inaccessible operational manual and crew training documentation

Verify manufacturers operational manual present and in working language understood by crew. Confirm manual includes operating limits per Appendix IV (capacity, fuel types, waste types). Check crew training records showing authorized personnel have completed incinerator operation training. Interview chief engineer and incinerator operators on operating procedures and prohibited materials.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #143929 · ✓ still in production