4-Takt-Hauptmotor · Hauptmotoren (4-Takt)
The MAN Energy Solutions 6LL48/60 is a medium‑speed, four‑stroke diesel main engine delivering about 7 200 kW at 514 rpm, designed for flexible fuel use (MGO/HFO) and proven reliability in commercial shipping.
Haben Sie das Herstellerdatenblatt zu diesem Modell? Schicken Sie es mit dem Anfrageformular — wir prüfen es und nennen die Quelle.
| Fuel Injector Overhaul/Replacement | 2,000 - 4,000 running hours |
|---|---|
| Cylinder Head Overhaul (Exhaust Valves, Inlet Valves) | 4,000 - 8,000 running hours |
| Piston Ring Renewal / Piston Inspection | 8,000 - 12,000 running hours |
| Connecting Rod Bearing Inspection/Renewal | 12,000 - 16,000 running hours |
| Cylinder Liner Measurement/Inspection | 16,000 - 24,000 running hours |
| Main Bearing Inspection/Renewal | 24,000 - 32,000 running hours |
| Major Overhaul (Engine Opened, Crankshaft Alignment, Full Bearing Renewal) | 48,000 - 64,000 running hours |
| Cylinder Liner Wear (Taper/Ovality) | Max. 0.6 - 0.8 mm (measured at top ring TDC and bottom of stroke) |
|---|---|
| Piston Ring Groove Wear (Axial Clearance) | Max. 0.15 - 0.20 mm increase from new specification |
| Connecting Rod Bearing Clearance | Max. 0.25 - 0.30 mm (plastigauge measurement) |
| Main Bearing Clearance | Max. 0.30 - 0.35 mm (plastigauge measurement) |
| Exhaust Valve Seat Recession | Max. 2.0 - 2.5 mm from original position (before reconditioning) |
| Crankshaft Deflection | Max. 0.05 - 0.08 mm (between adjacent webs, depending on engine length) |
Die Bereiche sind für diese Bauklasse typisch. Maßgeblich sind stets die Herstellerunterlagen zur jeweiligen Seriennummer.
Class surveyors typically focus on the functionality and certification of all engine safety devices (overspeed trip, low lube oil pressure shutdown, high jacket water temperature shutdown, oil mist detector alarms, and crankcase relief valve integrity). They review engine logbook entries for consistent performance trends (exhaust temperatures, pressures, fuel consumption) and scrutinize planned maintenance system (PMS) records, defect reports, and spare parts consumption to ensure proper upkeep. The integrity of the fuel oil system, including purifiers, heaters, and changeover arrangements (HFO/MGO), is thoroughly checked for leaks and proper operation. Recent crankshaft deflection readings are reviewed to assess bearing and alignment condition. Overall engine room cleanliness, absence of leaks, proper lagging of hot surfaces, and secure pipe/cable runs are also critically assessed.
Geschätzte Lebensdauer: 100,000 - 120,000 hours before major component replacement or full engine rebuild, with diligent maintenance and adherence to service schedules.
Kostenlos — senden Sie uns Ihre Anfrage zu MAN Energy Solutions-Ausrüstung. Unser Team prüft sie und antwortet per E-Mail.
Weitere Modelle desselben Ausrüstungstyps, zuerst MAN Energy Solutions.
Sagen Sie uns, was Sie für diesen MAN Energy Solutions 6LL48/60 benötigen — ein Ersatzteil, einen Serviceeinsatz, eine zweite Meinung. Sind Sie MAN Energy Solutions? Diese Herstellerseite beanspruchen.
Servicetechniker? Schreiben Sie den Tagesbericht für diesen 6LL48/60 in OceanSphere Work — Fotos, Stunden und Teile, als PDF für den Reeder. 14 Tage kostenlos testen →
Ja. Technische Daten, Dokumente und Servicehinweise zu diesem Modell sind ohne Konto lesbar. Ein Konto bringt gespeicherte Suchen und Anfragen dazu, es nimmt nichts weg.
Ja. Nennen Sie uns Hersteller, Modell und Bedarf — ein Mensch liest jede Anfrage und antwortet per E-Mail.
Schicken Sie uns das Typenschild oder den richtigen Wert. Wir prüfen ihn gegen das Herstellerdatenblatt oder den Klassifikationsdatensatz und aktualisieren die Seite.