Ocean Signal E101 Cat I Float-Free HRU Hammar H20 is identified in the source list as a epirb (406 mhz) category i. It is stowed, mounted or worn at the emergency location appropriate to the approved beacon or transponder type so it can be activated or released as intended. Its purpose is to support distress alerting, survivor location or search-and-rescue detection according to the radio service identified by the category. The source record provides no additional model-specific operating figure beyond the listed designation and category. Activation method, antenna arrangement, GNSS capability, float-free release and transmitted identity depend on the exact approved model. The exact model designation distinguishes radio function, activation arrangement and certification from neighboring emergency beacons or transponders; refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

frequency mhz 406
gps equipped True
battery life h 48
solas approved True
float free True
hru type Hammar H20

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Battery depletion or expiry caused by age, self-discharge or poor storage, resulting in failed self-test or reduced emergency endurance
Antenna or housing damage caused by impact, corrosion or water ingress, resulting in poor transmission or failed self-test
Activation-switch, release or mounting failure caused by corrosion, contamination or mechanical damage, resulting in inability to activate or release the unit as intended
Programming or identity error caused by incorrect replacement or configuration, resulting in incorrect identification being transmitted or recorded
Internal electronic or self-test failure caused by component faults, resulting in warning indications or inability to complete the approved test

Service & Maintenance

Inspect the housing, antenna, mounting, release mechanism and markings for damage or deterioration. Check battery and hydrostatic-release dates where those items form part of the approved unit. Perform self-tests strictly according to manufacturer instructions and avoid unintended distress transmissions. Verify programmed identity and registration information after replacement or servicing. Keep the unit accessible and correctly secured in its approved location. Refer to the manufacturer documentation for the exact figure for servicing, shore-maintenance and test requirements.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.