"> MSA Safety MSA Safety CalGas H2S/SO2 Dual-C
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 1 verified suppliers & service companies for MSA Safety in the Maritime Network Find suppliers →
MSA Safety

MSA Safety CalGas H2S/SO2 Dual-C

MSA Safety MSA Safety CalGas H2S/SO2 Dual-C is a shipboard unit in the Gas Detection group, classified in the source as Fixed Gas Detection System. It is normally installed as fixed sensors in hazardous/enclosed spaces or as portable instruments carried for atmosphere testing and personal protection. Its primary duty is to detect toxic, combustible or oxygen-deficient/enriched atmospheres before they create an unsafe condition. In service it interfaces with sensors, sampling pumps where fitted, alarm panels, calibration ports, local audible/visual alarms and safety shutdown systems. Compared with neighboring entries in the same product family, this record is the exact MSA Safety MSA Safety CalGas H2S/SO2 Dual-C variant; the model designation should be retained unchanged when matching onboard documentation and spares. For exact limits, settings, test values and approved maintenance criteria, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

type Calibration Gas Kit
gas mix H2S/SO2 Dual

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Sensor poisoning, depletion or ageing, typically indicated by slow response, failed bump test or calibration drift
Sampling pump/filter blockage in pumped units, typically indicated by low-flow alarm or no gas response
Battery/power-supply failure, typically indicated by instrument shutdown or low-power alarm
Water/dirt ingress into sensor or sample path, typically indicated by erratic readings or sensor fault
Calibration or configuration error, typically indicated by incorrect zero/span, nuisance alarms or missed response

Service & Maintenance

Inspect sensor condition, filters/sample paths, power/battery, alarm functions and calibration status; perform bump and calibration tests using approved gas and procedures, with exact alarm points taken from vessel/manufacturer documentation.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep approved sensors, filters, sampling tubing, batteries/chargers, pump service parts and calibration accessories/gas as allowed by the vessel's safety system.
Equipment Model #140969 · ✓ still in production