OceanSphere
Engines
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 6 verified suppliers & service companies for Dräger in the Maritime Network Find suppliers →
Dräger

PIR 7000 Open Path Mk2

Dräger PIR 7000 Open Path Mk2 — Gas Detection. It is normally installed in the protected space, on the person, or at a fixed detector point according to the listed system. Its primary purpose is to detect hazardous gas, oxygen condition, smoke, heat or another safety-related atmosphere or fire indication. Fixed, portable, open-path, smoke and heat detectors use different sensing principles, so calibration and testing must match the actual sensor type. The model designation identifies the listed configuration, but no additional meaning is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

sil2 True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Sensor ageing, poisoning, contamination or dirt causes drift, slow response, false alarms or failed tests
Power, battery, wiring or communication faults cause device-failure alarms or loss of indication
Water ingress, corrosion or impact damage causes intermittent operation or failed controls
Blocked sampling paths or obstructed detector exposure delays response or prevents correct detection
Incorrect calibration, configuration or detector type causes misleading readings or nuisance alarms

Service & Maintenance

Inspect sensors, sample paths or detector openings, wiring, power, mounting and alarm interfaces. Perform bump tests, functional tests or calibration using the approved method for the device type. Review alarm history and confirm remote indications. Refer to the manufacturer documentation for the exact figure for calibration and alarm criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry detector heads or sensor cartridges, filters, sampling parts, batteries or chargers, fuses, calibration accessories and approved test consumables.
Equipment Model #135614 · ✓ still in production

Wer liefert dieses Teil? 20 Betriebe im Verzeichnis · 10 aus Herstellerlisten

West Sea
Viana do Castelo, Portugal
A 2 Z Ship Stores
Guindy North, India
Anchor Marine Equipment Company Llc
United Arab Emirates
Art Of Marine
Aşağimüslimler, Turkey
BOSSS MARINE NAMIBIA (PTY) LTD.
Allan Dean Martin Street, Namibia
Bronia Gmbh
Germany
Diving Consultancy
Germany
Dräger Nederland B.V.
Haarlem, Netherlands
Eastwind Safety Equipment Services
United Arab Emirates
Fristad Plast AB
Fristad, Sweden
Hansa Safety Services BV
Punteweg 16a, Netherlands
Intermarine LLC
New Orleans, United States
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Draeger Sicherheitstechnik GmbH · GermanyDräger Marine & Offshore B.V. · NetherlandsGarant Global (acting as Garant Group) · LithuaniaKOMPRESSOR GROUP SRL · ItalyKONTES MARINE LP · GreeceMarahrens · GermanyMetromac Marine Automation · United Arab EmiratesOceanUs Korea · South KoreaResmar Ltd Leading supplies in fire and safety equipment · United KingdomTINO GENERAL ESSENTIAL LIMITED · Nigeria
Alle Betriebe für Dräger ansehen →