Minimax Marine

Minimax Marine IG-55 10kg-B

Minimax Marine Minimax Marine IG-55 10kg-B is identified in the source list as a fm-200/novec system. It is normally installed or arranged in the protected machinery, cargo or accommodation spaces. Its purpose is to suppress or extinguish fire with the listed fixed medium. The source record provides no additional model-specific operating figure beyond the listed designation and category. The equipment is based on agent storage, release controls, piping, valves and nozzles. The exact model designation distinguishes the installed configuration from neighboring variants in the same category; refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

agent IG-55
charge 10kg

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Loss of extinguishing-agent inventory or pressure caused by leakage or poor maintenance, resulting in low-level or low-pressure indication and reduced readiness
Nozzle, pipe or distribution blockage caused by corrosion, paint, deposits or mechanical damage, resulting in restricted discharge
Release-valve or actuator failure caused by corrosion, sticking or control faults, resulting in inability to discharge the system when commanded
Detection, interlock or alarm failure caused by wiring, sensor or panel faults, resulting in missing alarms or inhibited release sequence
Pump, cylinder or pressure-regulating equipment deterioration caused by wear, corrosion or electrical faults, resulting in inadequate discharge performance

Service & Maintenance

Inspect agent storage, pumps or cylinders, release controls, section valves, nozzles, piping and alarms in accordance with the approved maintenance plan. Keep nozzles and discharge openings clear of paint, cargo or modifications. Function-test release circuits and interlocks using the authorized non-discharge test method. Check cylinder or tank condition, pressure indication and securing arrangements and record any isolated section. Verify protected-space shutdowns and alarms where required. Refer to the manufacturer documentation for the exact figure for test intervals, charge quantities, pressures and acceptance criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep approved valve service kits, nozzles, seals, actuators, release components, fuses and manufacturer-recommended pump or pressure-regulating parts. Extinguishing-agent and cylinder components must remain compatible with the certified system.
Equipment Model #134305 · ✓ still in production