Tyco / Johnson Controls Tyco Novec 1230 50kg-B — Fixed Fire Suppression.

Inspector Detail

Common issues

  • Loss of agent pressure/weight over time from cylinder valve or fitting leakage
  • Corrosion on cylinder brackets and piping in the machinery space environment
  • Actuation solenoid or pilot line failure preventing automatic discharge
  • Detection system (smoke/heat detectors) false alarms or failure to trigger release
  • Discharge nozzles blocked or fouled by paint overspray or debris
  • Manual release cable or pull station corrosion/seizure
  • Compartment integrity failures (damaged seals, unsealed penetrations) reducing agent hold time below the required duration

Inspection checklist

  • Check cylinder pressure gauge / liquid level indicator against the maker's acceptable range
  • Weigh cylinders (or check level gauge) to confirm agent quantity is within tolerance
  • Visual inspection of piping, brackets and nozzles for corrosion, damage or blockage
  • Function test detection and alarm system per the maker's procedure
  • Inspect manual release stations and pull cables for free movement
  • Check protected space door closure and ventilation shutdown interlocks
  • Verify time-delay and pre-discharge alarm operation
  • Check safety signage and operating instructions at protected space entrances

Service intervals

Cylinder weight/pressure check typically every 12 months
Full function test (detection/actuation, agent isolated) typically annually per maker/class requirement
Internal cylinder inspection typically every 5 years or per the maker's certification cycle
Detector sensitivity test typically annually

Typical wear limits

Agent quantity loss typically requires service/refill if loss exceeds around 5% of nominal charge weight - confirm against the maker/class acceptance limit
Superpressurization gauge reading assessed against the green band marked on the specific cylinder - confirm against the maker's chart

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Actuation solenoid valve
  • Pilot actuator head
  • Detector heads
  • Manual pull cable assembly
  • Cylinder valve seal kit

Safety

  • Discharge displaces oxygen in the protected space and personnel must evacuate on alarm
  • Thermal decomposition byproducts can form if the agent contacts very hot surfaces during discharge
  • Cylinders are stored under pressure (nitrogen superpressurized) - do not work on them without isolating pressure and following maker guidance
  • Risk of inadvertent discharge during maintenance if the system is not properly isolated

Class survey

Fixed clean-agent fire suppression systems are subject to annual survey with weight/pressure checks and periodic full function tests; documentation of agent quantity, cylinder inspection dates and detector test records is typically required at each machinery or safety equipment survey.

Components & Design

Component data being added…

Technical Data

agent Novec 1230
charge 50kg

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #134254 · ✓ still in production