Kidde Marine / Carrier

Kidde Marine CO2 LP 21bar 5000kg-B

Kidde Marine / Carrier Kidde Marine CO2 LP 21bar 5000kg-B is listed as a CO2 Fixed Fire System within the Fixed Fire Suppression category. It is typically installed in protected machinery, cargo or accommodation zones together with a dedicated agent, pump, valve and release arrangement as applicable. Its engineering role is to suppress or control a shipboard fire by distributing the specified extinguishing medium through an approved fixed system. The complete model designation should be retained when matching drawings, certificates, service information and spare parts because neighboring variants may differ in configuration even when they share the same equipment family. The exact shipboard arrangement and interfaces remain installation-specific and should be checked against the vessel’s approved drawings and equipment documentation. Where an operating value, tolerance, wear limit or setting is not explicitly stated in the source data, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

charge kg 5000
pressure LP 21bar

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Closed, seized or incorrectly positioned isolation valves can block discharge, detected during functional checks or by valve-position indication
Loss of agent, water or system pressure through leakage can reduce readiness, seen as low-pressure indication or inventory discrepancy
Blocked or damaged nozzles and distribution piping can impair coverage, found by inspection or flow testing
Release-circuit, solenoid or control-panel faults can prevent actuation, seen as failed tests or system alarms
Corrosion, contamination or mechanical damage to storage and piping components can compromise integrity, found during inspection or pressure-related checks

Service & Maintenance

Inspect agent or water supply, release controls, alarms, valves, distribution piping, nozzles and protected-space interfaces. Confirm remote and local release arrangements, shutdown interlocks and system status indications are intact. Test intervals, agent quantities and pressure limits not provided in the source entry must be taken from the approved fire-control plan and manufacturer documentation.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Onboard spares should follow the approved system list and may include release-device consumables, seals, valve service items, nozzles, fuses and control-panel components.
Equipment Model #134155 · ✓ still in production