Xtralis / Honeywell

VESDA-E VEP-A02

Xtralis / Honeywell VESDA-E VEP-A02 — Fire Detection Systems. The supplied category identifies the equipment as Smoke Detector, and it is normally installed in accommodation, machinery, cargo-related or service spaces connected to the vessel fire-detection loop or zone. In that listed role, its primary purpose is to detect smoke, heat or flame and initiate an alarm at the fire-detection panel. Smoke, heat and flame detectors use different sensing principles and are selected for the protected environment, so test methods and susceptibility to contamination differ. Within the supplied list, neighbouring variants are distinguished by their model designations and naming, while the source does not state further model-specific hardware differences. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Xtralis / Honeywell VESDA-E VEP-A02

Components & Design

Component data being added…

Technical Data

type Aspirating
very early warning True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Dust, salt, oil or contamination at the sensing element causes false alarms, reduced sensitivity or failed tests
Water ingress or condensation causes intermittent alarms or detector failure
Loop wiring, base or address faults cause missing-device or communication alarms
Paint, covers or physical obstruction prevents the detector from sensing the protected space correctly
Ageing electronics or sensor deterioration causes repeated nuisance alarms or failure during test

Service & Maintenance

Inspect detector cleanliness, base, wiring, identification and unobstructed exposure to the protected space. Perform functional testing with the approved method for the sensing principle and verify correct alarm location at the panel. Investigate recurring nuisance alarms rather than disabling the detector. Refer to the manufacturer documentation for the exact figure for testing and replacement criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry compatible detector heads, bases, loop isolators where used, fuses and approved test accessories.
Equipment Model #133989 · ✓ still in production