Dräger Drager Polytron 8000 HCN is listed in this library as a marine gas-detection instrument or system in the Gas Detection / Fixed Gas Detection System category. Equipment of this class is typically installed at fixed sampling points, machinery and cargo spaces, accommodation boundaries, or as a portable unit carried by personnel according to the detection duty. Its shipboard purpose is to warn personnel of hazardous gas concentrations, oxygen deficiency or enrichment, or combustible atmosphere conditions. The exact piping, electrical, control, foundation, and accessory arrangement depends on the vessel and the supplied configuration. No additional verified rating, capacity, weight, dimension, or operating limit is provided in the source entry. Where adjacent models in the same product family differ in rating, size, materials, control options, certification, or accessories, refer to the manufacturer documentation for the exact model-specific differences.

Components & Design

Component data being added…

Technical Data

target gas HCN
sil rated True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Sensor poisoning, ageing, contamination, or end-of-life degradation causes slow response, failed calibration, or readings that drift from known test gas
Blocked sample line, filter, pump, or diffusion path prevents representative gas reaching the sensor and causes low or delayed readings
Battery, supply, charger, or internal power faults cause shutdown, short operating time, or power alarms
Water ingress, condensation, corrosion, or damaged connectors produces intermittent channels, false alarms, or failed communication
Calibration, configuration, relay, or control faults can cause nuisance alarms, missing alarms, or incorrect display of the monitored point

Service & Maintenance

Inspect sensor condition, sampling paths and filters, pump operation where fitted, battery or power supply, alarms, relays, display, identification of sampling points, and calibration records. Perform bump tests and calibration only with approved gas and according to the manufacturer and vessel safety procedure.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep approved sensors or sensor cartridges, filters, pump or tubing service items, batteries or charging accessories, calibration fittings, and critical fuses or interface parts recommended for the system.
Equipment Model #130618 · ✓ still in production