OceanSphereENGINES
Library› Safety & LSA› Gas Detection› Fixed Gas Detection System› Dräger Drager Polytron 8000 H2S

Drager Polytron 8000 H2S

Fixed Gas Detection System · Gas Detection

Class-certified type (DNV register) · technical data sheet not yet verified​‌⁠⁠⁠‍​⁠‌‌‌‌‌‌​‌⁠‍‍‌

Dräger Drager Polytron 8000 H2S is listed in this library as a marine gas-detection instrument or system in the Gas Detection / Fixed Gas Detection System category. Equipment of this class is typically installed at fixed sampling points, machinery and cargo spaces, accommodation boundaries, or as a portable unit carried by personnel according to the detection duty. Its shipboard purpose is to warn personnel of hazardous gas concentrations, oxygen deficiency or enrichment, or combustible atmosphere conditions. The exact piping, electrical, control, foundation, and accessory arrangement depends on the vessel and the installed configuration. Where adjacent models in the same product family differ in rating, size, materials, control options, certification, or accessories, refer to the manufacturer documentation for the exact model-specific differences.

Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Target gasH2S
Sil ratedYes
Service

Service notes.

What our service work and the manufacturer documentation say about keeping this model running.

Inspect sensor condition, sampling paths and filters, pump operation where fitted, battery or power supply, alarms, relays, display, identification of sampling points, and calibration records. Perform bump tests and calibration only with approved gas and according to the manufacturer and vessel safety procedure.

Inspection

Common failures & inspection points

Spares

Replacement Parts

Spare parts notes

Keep approved sensors or sensor cartridges, filters, pump or tubing service items, batteries or charging accessories, calibration fittings, and critical fuses or interface parts recommended for the system.

Need this part?

Request a quote for this model.

Free of charge — send us your request for Dräger equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Fixed Gas Detection System.

Other models of the same equipment type, Dräger first.

By manufacturer RKI InstrumentsDrägerRiken KeikiMSA SafetyCrowconAFRISOHoneywell AnalyticsDet-TronicsIndustrial ScientificGfG InstrumentationDräger Safety AG & Co. KGaAHanla IMSAutronicaEndress+HauserVaisalaAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Dräger models More like Drager Polytron 8000 H2S
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Dräger Drager Polytron 8000 H2S — a part, a service call, a second opinion. Are you Dräger? Claim this brand page.

Service engineer? Write the day report for this Drager Polytron 8000 H2S in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.