Dräger

Drager X-am 2500 LEL/O2/H2S/SO2

Dräger Drager X-am 2500 LEL/O2/H2S/SO2 is listed as a marine portable multi-gas detector in the Gas Detection / Portable Multi-Gas Detector category. Equipment of this class is typically installed at fixed sampling points or as a portable instrument carried into machinery, cargo, enclosed, or accommodation-adjacent spaces according to the detection duty. Its shipboard purpose is to warn personnel of hazardous gas concentrations, oxygen deficiency or enrichment, or combustible atmosphere conditions. The exact piping, electrical, control, foundation, and accessory arrangement depends on the vessel and the supplied configuration. No additional verified rating, capacity, weight, dimension, or other model-specific figure is supplied in the structured source data. Any differences from adjacent models in the same family, including rating, size, material, control, certification, or accessory differences not explicitly listed here, should be confirmed in the manufacturer documentation.

Components & Design

Component data being added…

Technical Data

gases LEL/O2/H2S/SO2
atex certified True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Sensor poisoning, ageing, contamination, or end-of-life degradation causes slow response, failed calibration, or drifting readings
Blocked sample line, filter, pump, or diffusion path prevents representative gas reaching the sensor and causes low or delayed readings
Battery, supply, charger, or internal power faults cause shutdown, short operating time, or power alarms
Water ingress, condensation, corrosion, or damaged connectors produce intermittent channels, false alarms, or failed communication
Calibration, configuration, relay, or control faults can cause nuisance alarms, missing alarms, or incorrect identification of the monitored point

Service & Maintenance

Inspect sensor condition, sampling paths and filters, pump operation where fitted, battery or power supply, alarms, relays, display, sampling-point identification, and calibration records. Perform bump tests and calibration only with approved gas and according to manufacturer and vessel safety procedures.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep approved sensors or sensor cartridges, filters, pump or tubing service items, batteries or charging accessories, calibration fittings, and critical fuses or interface parts.
Equipment Model #130571 · ✓ still in production