Fireboy-Xintex

Fireboy MA2 200 cu ft

Fireboy-Xintex Fireboy MA2 200 cu ft — Fixed Fire Suppression. The supplied category identifies the equipment as FM-200/Novec System, and it is normally installed in protected machinery, accommodation or service spaces with storage, pumps or cylinders, distribution piping, nozzles and release controls appropriate to the extinguishing medium. In that listed role, its primary purpose is to suppress or extinguish fire using the approved fixed extinguishing agent or water-based system. CO2, Novec, clean-agent, foam, sprinkler, water-mist and dry-chemical systems use different media and hazards, so release sequence and testing must match the approved fire plan. Within the supplied list, neighbouring variants are distinguished by their model designations and naming, while the source does not state further model-specific hardware differences. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

agent HFC-227ea
automatic True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Loss of extinguishing medium, cylinder pressure or water supply reduces available firefighting capacity
Valve, nozzle, pump or release-system faults prevent correct discharge into the protected area
Corrosion, seal deterioration or mechanical damage causes leakage or unreliable operation
Detection, alarm, fan-stop or shutdown interlock faults create an incomplete or unsafe release sequence
Blocked nozzles, hoses or distribution piping reduce agent delivery to the fire area

Service & Maintenance

Inspect storage or pumps, valves, nozzles, piping, release controls, alarms and shutdown interfaces according to the system type. Verify access control, protected-space arrangements and signs of leakage or corrosion. Functional tests must follow the approved safety procedure without unintended discharge. Refer to manufacturer, class and statutory documentation for the exact figure for pressure, quantity and acceptance criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry approved valve or solenoid parts, pump seals where applicable, release components, alarms, fuses, nozzles and manufacturer-supported service parts.
Equipment Model #130192 · ✓ still in production