Hochiki Marine Hochiki Conv 32-Zone — Fire Detection Systems. The supplied category identifies the equipment as Conventional Fire Detection Panel, and it is normally installed in the bridge, fire-control station or continuously attended control position with detection loops or zones connected throughout the vessel. In that listed role, its primary purpose is to supervise fire detectors, identify alarm locations and distribute fire and fault alarms. Addressable panels identify individual devices, while conventional panels identify zones; both depend on healthy loops, control power, backup batteries and correctly configured alarm outputs. Within the supplied list, neighbouring variants are distinguished by their model designations and naming, while the source does not state further model-specific hardware differences. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

zones 32

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Loop or zone wiring faults cause open-circuit, short-circuit or missing-device indications
Backup-battery or power-supply faults cause charger alarms, reduced standby capability or panel reset
Detector addressing or configuration errors cause incorrect alarm location or missing devices
Display, processor or communication faults cause frozen indications or loss of remote repeater information
Relay or output-interface faults prevent required remote alarms, fan stops or fire-safety actions

Service & Maintenance

Review panel faults, loop or zone status, batteries, charger, repeaters and output interfaces. Test representative detectors and verify correct location text and remote alarm transmission under the approved fire-testing procedure. Maintain controlled backups of address and cause-and-effect configuration where applicable. Refer to the manufacturer and fire-control documentation for the exact figure for battery, loop and test limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry compatible detector bases or loop modules, fuses, backup batteries, power supplies, relays and supported panel or repeater modules.
Equipment Model #130065 · ✓ still in production