"> Aalborg Industries (Alfa Laval) Calorifier XC
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 15 verified suppliers & service companies for Aalborg Industries (Alfa Laval) in the Maritime Network Find suppliers →
Aalborg Industries (Alfa Laval)

Calorifier XC

The Aalborg Calorifier XC is a compact dual‑source hot water calorifier that supplies potable water using engine waste heat/steam at sea and electric heating in port. The supplied category identifies the equipment as Hot Water Calorifier, and it is normally installed in the domestic freshwater machinery space with pumps, pressure vessel or calorifier, controls and distribution piping. In that listed role, its primary purpose is to maintain domestic water pressure or provide hot water to accommodation and service consumers. Hydrophore units and calorifiers have different functions, but both depend on sound pressure control, tanks, valves and sanitary water condition. The model designation identifies the listed configuration, but no additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. The source metadata also states capacity: 300-3000 L. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Aalborg Industries (Alfa Laval) Calorifier XC
300-3000 L
Capacity
Freshwater/Steam
Medium

Components & Design

Component data being added…

Technical Data

medium Freshwater/Steam
type Combined Calorifier

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Pump, heater or control failure causes low pressure, poor hot-water supply or repeated cycling
Pressure-switch, thermostat or level faults cause unstable operation or protective trips
Air-charge loss, vessel leakage or failed non-return valves cause frequent pump starts or pressure fluctuation
Scale or internal deposits reduce heating or water-flow performance
Seal, flange or relief-valve leakage causes visible water loss and corrosion

Service & Maintenance

Inspect pumps or heaters, pressure vessel or calorifier, valves, controls, relief devices and leakage. Check pressure cycling, hot-water temperature stability and sanitary condition under the vessel maintenance program. Verify safety valves and electrical protection using approved procedures. Refer to the manufacturer documentation for the exact figure for pressure, temperature and service settings.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry pump seals, pressure switches, thermostats, heater elements where fitted, non-return valve parts, gaskets and control relays.
Equipment Model #1282 · ✓ still in production