Dishwasher Small 230V Marine
MKN Marine Dishwasher Small 230V Marine — 10 kW.
Inspector Detail
▸
Common issues
- Limescale buildup on the heating element and wash arm jets reducing wash performance
- Door seal degradation causing leaks
- Blocked wash arm nozzles from food debris
- Drain pump blockage or failure
- Thermostat or thermal cut-out faults affecting wash/rinse temperature
- Electrical connection corrosion in the galley's humid environment
Inspection checklist
- Check door seal condition and closing mechanism
- Clean/descale wash arms and spray nozzles
- Check final rinse temperature against the sanitising requirement on the unit's data plate
- Test the drain pump and check the drain filter/strainer for debris
- Inspect the electrical supply cable, plug, and earth/ground bonding
- Check detergent/rinse-aid dosing pump operation
- Verify door interlock/safety switch function
- Check for scale or corrosion inside the tank
Service intervals
| Descaling | per local water hardness, typically monthly to quarterly |
| Wash arm/nozzle cleaning | weekly |
| Door seal inspection | quarterly |
| Electrical safety check (insulation/earth bonding) | annually, per the vessel's electrical safety programme |
| Drain pump/filter cleaning | weekly |
Typical wear limits
| Final rinse temperature | should meet the sanitising temperature stated on the unit's own data plate - confirm against the nameplate rather than assuming a fixed figure |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Critical spares
- Door seal/gasket
- Wash arm assembly/spray nozzles
- Drain pump
- Heating element
- Detergent/rinse-aid dosing pump
- Door interlock switch
Safety
- Hot water/steam release risk when the door is opened mid-cycle
- Wet galley environment - confirm earth bonding and RCD/ELCI protection before use
- Descaling chemicals require PPE and adequate ventilation
- Door interlock must be functional before the unit is returned to service
Class survey
Galley equipment of this kind generally falls outside classification machinery survey scope but is covered by the vessel's food hygiene/MLC habitability requirements and general electrical safety inspection - confirm the applicable flag/class treatment.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →