Parker Hannifin Marine PV Valve DN300 SS316L Marine is listed as a Pressure/Vacuum Relief Valve (PV Valve) within the PV Valves & Vent Systems category. It is typically installed on cargo-tank or vent piping exposed on deck, forming part of the controlled tank-breathing and over/under-pressure protection arrangement. Its engineering role is to relieve excessive positive or negative tank pressure while remaining closed during normal conditions within the approved operating range. The complete model designation should be retained when matching drawings, certificates, service information and spare parts because neighboring variants may differ in configuration even when they share the same equipment family. The exact shipboard arrangement and interfaces remain installation-specific and should be checked against the vessel’s approved drawings and equipment documentation. Where an operating value, tolerance, wear limit or setting is not explicitly stated in the source data, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

nominal diameter dn 300
set pressure mbar 2100
vacuum mbar -350
material SS316L

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Deposits, corrosion or sticky residues can prevent the valve pallet or mechanism from moving freely, seen as failed functional checks or abnormal tank pressure behavior
Seat or seal damage can cause leakage at pressures where the valve should remain closed, noticed as vapor release or inability to maintain expected tank pressure
Flame-screen or vent-path blockage where fitted can restrict breathing capacity, seen as abnormal pressure response during cargo operations
Mechanical damage or incorrect reassembly can alter opening behavior, detected during bench or onboard testing
Icing, contamination or weather exposure can impair movement, producing intermittent sticking in adverse conditions

Service & Maintenance

Inspect the body, seat, moving elements, screens and drains for corrosion, deposits and free movement. Verify set-point behavior only using the approved test method and calibrated equipment. Opening and closing pressures must not be inferred from the model name unless explicitly stated; refer to the manufacturer documentation for the exact figure.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry approved seals, seat components, screens, gaskets and other maker-recommended service parts appropriate to the installed valve.
Equipment Model #121445 · ✓ still in production