PV Valve DN200 SS316L Marine
Pres-Vac PV Valve DN200 SS316L Marine — PV Valves & Vent Systems.
Inspector Detail
▸
Common issues
- Pallet/seat fouling from cargo vapour residue or icing, preventing proper seating
- Corrosion of valve body or pallet reducing set-pressure accuracy
- Seal (PTFE/elastomer) degradation causing leakage past the seat
- Set-pressure drift from spring fatigue or mechanical damage
- Flame screen blockage from product buildup, if fitted
- Pallet sticking from lack of lubrication or paint overspray during maintenance
- Drain hole blockage leading to water/condensate accumulation
Inspection checklist
- Visual check for external corrosion or damage to body and flange
- Manual lift/pop function test to confirm free pallet movement
- Check flame screen, if fitted, for blockage or damage
- Verify set pressure/vacuum on a test bench against the valve's own nameplate/certificate - do not assume a catalogue figure
- Inspect seat and pallet sealing surfaces for pitting or deposits
- Check drain holes are clear
- Confirm the valve tag/certificate matches its installed location and cargo service
- Inspect gaskets and fasteners for corrosion
Service intervals
| Visual inspection | annual |
| Function/pop test | annual or per class/cargo-type requirement |
| Bench test/recalibration | typically every 2-5 years or per the vessel's approved PV valve maintenance schedule |
| Flame screen cleaning | at each inspection, if fitted |
Typical wear limits
| Seat/pallet leak-tightness | assessed by bench test against the valve's own certified set point rather than a generic dimensional limit - confirm against the manufacturer's test certificate for this valve |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Critical spares
- Seat/pallet seal (PTFE or elastomer)
- Spring set matched to the required set pressure
- Flame screen element
- Gasket set
Safety
- Flammable/toxic vapour release at the vent outlet during testing
- Working at height on deck or vent riser
- Stored spring energy during disassembly
- Cargo vapour exposure - gas-test and use appropriate PPE before close approach
- Static discharge risk near cargo vent openings
Class survey
Note: the specific set-pressure and vacuum figures in the sourced specification are flagged as unverified and are not restated here as fact. PV valves for cargo tank venting are class/flag-surveyed items requiring approved test certificates, set-pressure verification traceable to type approval, and functional testing at the interval set by the vessel's approved maintenance system, typically tied to cargo tank venting system survey.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →