Bowman
Marine LO Cooler
Shell-and-tube LO cooler for marine engines. CuNi or titanium tubes.
50-500 kW
Capacity
LO/FW
Medium
🔧 Komponenten & Aufbau
Component data being added…
📊 Technische Daten
medium
LO/FW
type
Shell-and-Tube LO Cooler
⚠️ Typische Ausfälle
- ● Tube corrosion/erosion from seawater
- ● Tube bundle fouling
- ● End cover gasket leakage
- ● Zinc anode depletion
🔍 Service & Wartung
Replace zinc anodes annually. Hydroblast tube bundle at drydock. Monitor LO outlet temperature for fouling indication.
📦 Verschleißteile
Spare parts data being added…
Bowman: Dichtungssatz an Bord vorhalten. Platten-Reinigungschemikalien bevorraten. Lead time: 2-6 Wochen.