"> ENWA Marine Hydrophore 3m3h 6bar Marine
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 23 verified suppliers & service companies for ENWA Marine in the Maritime Network Find suppliers →
ENWA Marine

Hydrophore 3m3h 6bar Marine

ENWA Marine Hydrophore 3m3h 6bar Marine — Potable Water System. The supplied category identifies the equipment as Hydrophore / Pressure Set, and it is normally installed in the domestic freshwater machinery space between potable-water storage and the accommodation distribution system. In that listed role, its primary purpose is to maintain stable freshwater pressure for accommodation, galley, sanitary and service consumers. Compared with a single transfer pump, a pressure set combines pumps, pressure control and often a pressure vessel or staged pump logic to maintain demand automatically. Within the supplied list, neighbouring variants are distinguished by their model designations and naming, while the source does not state further model-specific hardware differences. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

capacity lpd 3000
treatment type Pressurization

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Pump seal or impeller wear causes leakage, low pressure or long pump running periods
Pressure-switch or pressure-transmitter faults cause rapid cycling, failure to start or unstable system pressure
Loss of pressure-vessel air charge or failed non-return valves causes frequent starts and pressure fluctuation
Suction restriction or low tank level causes noisy operation, low pressure or loss of prime
Motor, contactor or control faults cause one pump to remain unavailable or repeated electrical trips

Service & Maintenance

Inspect pumps, seals, non-return valves, pressure vessel where fitted, pressure sensors, controls and leakage. Observe start/stop cycling and confirm standby pump changeover where provided. Maintain sanitary cleanliness and investigate recurring pressure fluctuations. Refer to the manufacturer documentation for the exact figure for pressure, air charge and protection settings.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry pump seals, non-return valve parts, pressure switches or transmitters, contactors, fuses, gaskets and a critical pump or motor service kit where justified.
Equipment Model #114516 · ✓ still in production