"> MAN D2676 Emergency GenSet
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
MAN

D2676 Emergency GenSet

The MAN D2676 is a medium‑speed, diesel‑powered emergency generator set delivering approximately 397 kW, designed to provide immediate backup power for critical ship systems when the main plant fails. The supplied category identifies the equipment as Emergency Generator Set, and it is normally installed in an independent emergency-generator room or other approved location separated from the main machinery space. In that listed role, its primary purpose is to supply essential emergency electrical loads after loss of the main source of power. Compared with normal auxiliary generators, the emergency set has dedicated automatic-start, fuel, starting-energy and emergency-switchboard interfaces intended to remain available after a main-space casualty. The model designation identifies the listed configuration, but no additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. The source metadata also states power: 397.0 kW; capacity: 200-500 kVA. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

MAN D2676 Emergency GenSet
397.0 kW
Power
200-500 kVA
Capacity
Emergency Equipment
Medium

Components & Design

Component data being added…

Technical Data

power kw 397
type Emergency GenSet

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Battery, air or hydraulic starting-system faults cause failure to start automatically or locally
Fuel contamination, filter blockage or stale fuel causes unstable running or inability to accept load
Cooling, lubrication or belt faults cause overheating, low-pressure alarms or shutdown
Governor, AVR or sensor faults cause unstable frequency or voltage and failed load acceptance
Breaker, charger or automatic-start circuit faults prevent connection to the emergency switchboard

Service & Maintenance

Inspect fuel, starting energy, batteries or air, cooling, lubrication, exhaust, generator and emergency-switchboard interfaces. Test automatic start and load acceptance under the approved vessel procedure and review alarm history. Confirm the room, ventilation and independent services remain ready. Refer to the manufacturer and statutory documentation for the exact figure for test and operating limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry fuel and oil filters, belts, starter or battery support parts, sensors, relays, AVR or governor spares where justified, fuses and approved lubricants.
Equipment Model #1119 · ✓ still in production