"> Howden Marine HMF Centrifugal 30000m3h accommodation
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 6 verified suppliers & service companies for Howden Marine in the Maritime Network Find suppliers →
Howden Marine

HMF Centrifugal 30000m3h accommodation

Howden Marine HMF Centrifugal 30000m3h accommodation — 9.0 kW. The supplied category identifies the equipment as Centrifugal Fan, and it is normally installed in an engine-room, cargo-hold, accommodation or service-space ventilation duct or fan room according to the listed duty. In that listed role, its primary purpose is to move supply or exhaust air and maintain the required ventilation of the connected ship space. Axial, centrifugal, supply, exhaust and emergency-fire fans differ in pressure capability, flow path and emergency function, but all depend on sound rotating parts, unobstructed airflow and reliable motor control. Within the supplied list, this variant is distinguished from neighbouring entries by its model designation and the explicitly listed power; further hardware differences are not stated in the source. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

9.0 kW
Power

Components & Design

Component data being added…

Technical Data

air flow m3h 30000
static pressure pa 500
power kw 9.0
fan type centrifugal
zone accommodation

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Blade fouling, duct restriction or blocked guards reduce airflow and cause poor ventilation, high motor load or abnormal pressure
Bearing wear or lubrication deterioration causes rising vibration, rumbling noise or elevated bearing temperature
Impeller imbalance, corrosion or mechanical damage causes vibration and can lead to repeated motor or vibration trips
Motor, contactor or power-supply faults cause failure to start, phase-related alarms or unexpected shutdown
Loose foundations, flexible connections or damper faults cause structural vibration, air leakage or incorrect airflow distribution

Service & Maintenance

Inspect fan blades or impeller, bearings, guards, flexible connections, foundations, motor, starter and nearby dampers. Check for corrosion, fouling, abnormal vibration and unobstructed intake and discharge paths. Test remote start/stop and emergency functions where the fan is part of a fire or smoke-control system. Refer to the manufacturer documentation for the exact figure for airflow, vibration, bearing and electrical limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry bearings or bearing kits where serviceable, motor or starter spares, belts where fitted, flexible-connection material, vibration isolators, fuses and control relays.