Emerson Marine Fisher PV DN400 2450mbar is identified in the source list as a pressure/vacuum relief valve (pv valve). It is installed on cargo-tank vent piping, normally on the weather deck or at a designated vent mast or riser location. Its purpose is to control cargo-tank pressure and vacuum and, for high-velocity valves, discharge vapor in the approved manner during loading, discharge and thermal breathing. The source record provides no additional model-specific operating figure beyond the listed designation and category. Valve seat, pallet or spring arrangement, flame-protection features where applicable, weather protection and process connection form the venting device. The exact model designation distinguishes pressure-vacuum function, flow capacity, material and approval from neighboring vent valves; refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

nominal diameter dn 400
set pressure mbar 2450
vacuum mbar -350
material SS316

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Valve sticking caused by cargo residues, corrosion or salt deposits, resulting in abnormal tank pressure or failure to reseat
Seat or seal damage caused by wear, contamination or mechanical impact, resulting in continuous vapor leakage or inability to hold normal pressure
Flame screen or flow path blockage where fitted caused by dirt, paint or corrosion, resulting in restricted venting and rising tank pressure
Spring, pallet or mechanism deterioration caused by corrosion or fatigue, resulting in incorrect opening behavior or chatter
Heating or anti-icing failure where fitted caused by electrical or steam faults, resulting in icing and restricted venting in cold service

Service & Maintenance

Inspect valve body, seat, pallet or spring mechanism, weather cap, flame-protection parts and drain paths for corrosion, deposits and free movement. Keep vents free of paint and cargo residue and do not add unapproved screens or covers. Function-test opening and reseating using the approved workshop or onboard method. Check heating or anti-icing arrangements where fitted. Verify the valve remains matched to the approved cargo-tank vent system after replacement. Refer to the manufacturer documentation for the exact figure for opening pressure, vacuum setting, test flow and service limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep approved seat seals, gaskets, springs or pallets where serviceable, heating elements or tracing parts where fitted and manufacturer-recommended repair kits. Complete spare valves may be appropriate for critical tanker service. Replacement parts must preserve type approval and material compatibility.
Equipment Model #103371 · ✓ still in production