Akasol/BorgWarner

AKASystem 1000kWh NMC 1000V

Akasol/BorgWarner AKASystem 1000kWh NMC 1000V is identified in the source list as a lithium-ion battery system (ess). It is normally installed or arranged in the dedicated battery or electrical room. Its purpose is to store electrical energy or maintain uninterrupted supply to critical consumers. The source record provides no additional model-specific operating figure beyond the listed designation and category. The equipment is based on battery modules or UPS power electronics, protection, cooling and monitoring. The exact model designation distinguishes the installed configuration from neighboring variants in the same category; refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

capacity kwh 1000
chemistry NMC
cycle life 4000
c rate 1.0
class approval DNV GL

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Loose or degraded electrical connection caused by thermal cycling, vibration or poor termination, resulting in local overheating, phase imbalance or intermittent faults
Power-electronic, breaker or contactor failure caused by aging, overload or electrical stress, resulting in trips, inability to switch or loss of output
Cooling or ventilation failure caused by blocked filters or fan wear, resulting in elevated internal temperature and protective alarms
Insulation deterioration caused by moisture, salt, heat or contamination, resulting in earth faults, low insulation resistance or nuisance trips
Control, protection or communication failure caused by sensor, relay, network or configuration faults, resulting in incorrect operation or unavailable functions

Service & Maintenance

Inspect enclosure condition, ventilation, power and control terminals, protective devices, earthing and signs of overheating with the equipment safely isolated. Review trip and alarm history and investigate recurring faults before resetting. Check insulation, cable glands and cleanliness and correct any moisture or salt contamination. Function-test protective, interlock and control functions using approved procedures. Preserve settings and configuration before replacing electronic modules. Refer to the manufacturer documentation for the exact figure for torque values, electrical tests, protection settings and service limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep fuses, relays, contactors or breaker auxiliaries, cooling fans, power-supply or control modules and manufacturer-recommended electronic spares. Critical equipment may justify a complete spare module or unit. Preserve parameter and configuration backups where applicable.
Equipment Model #95626 · ✓ still in production