Leclanché Marine TiBox 1000kWh LFP 700V — Battery & UPS Systems. The supplied category identifies the equipment as Lithium-Ion Battery System (ESS), and it is normally installed in a dedicated battery room, battery container or protected electrical space with charging, monitoring and ventilation or cooling appropriate to the installed technology. In that listed role, its primary purpose is to store electrical energy for emergency supply, ride-through, control power, hybrid propulsion support or other shipboard electrical functions. Lithium-ion ESS, marine UPS and BMS equipment differ in energy scale and control architecture, but all depend on reliable cell condition, charging, isolation and thermal management. Within the supplied list, neighbouring variants are distinguished by their model designations and naming, while the source does not state further model-specific hardware differences. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

capacity kwh 1000
chemistry LFP
cycle life 6000
c rate 1.0
class approval DNV GL

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Cell or battery ageing causes reduced usable capacity, voltage imbalance or low-runtime alarms
Cooling or ventilation failure causes rising battery temperature, thermal alarms or derating
BMS, charger, inverter or communication faults cause loss of availability, bypass operation or automatic isolation
Insulation deterioration or DC earth faults cause insulation alarms and may block connection to the electrical system
Loose high-current terminals or degraded interconnections cause local heating, voltage drop or intermittent supply

Service & Maintenance

Review battery or BMS alarms, voltage and temperature trends, insulation monitoring, charging, cooling and emergency isolation. Inspect enclosures, terminals and cable joints for heat damage, corrosion or movement. Verify charger, inverter, bypass and backup functions under the approved vessel procedure. Refer to the manufacturer documentation for the exact figure for voltage, state-of-charge, temperature and replacement limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry approved fuses, contactors, charger or inverter modules where supported, temperature or voltage sensors, cooling components and replacement battery modules according to the vessel support plan.
Equipment Model #95292 · ✓ still in production