Glamox C65 Cabin 20W IP66 4000K
Glamox Marine Lighting. Glamox Marine specializes in LED lighting for ships, offshore and wind power installations with explosion-proof (ATEX/IECEx) and corrosion-resistant designs. The product lines include interior and exterior luminaires for Zone 1/2 according to EN 60079. All devices are designed for harsh marine environments with salt water, high-pressure cleaning u
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Common failures & inspection points
Visuell: Korrosion an Gehäuse, Glands, Befestigungen (Rost, Pitting); Funktionell: IEC 60529 Wasserstrahl-Test (IPX5/6 für Hochdruck-Reinigung, IPX7/8 für Eintauchbereiche); Dichtheitsprüfung Gehäuse, Gasketeintegrität (Silikon/EPDM bevorzugt)
Verify certificate (Unit Verification or Type Exam + Product Verification); check Zone 2/22 compliance; label/marking on luminaire (II 2G Ex eb mb IIC T4 Gb); annual inspection by qualified person (CompEx-certified); document any changes to equipment
Functional test: AC voltage shutdown > 3 seconds, confirm LED activation; visual battery inspection (corrosion, secure connections); load test (annually): minimum duration 1.5 h (E1) or 3 h (E3) with ≥50 lux lighting on evacuation route; SOLAS compliance (automatic activation on power failure)
Surface inspection: 316L stainless steel for pitting, scratches (ASTM B117 salt spray standard); fasteners for corrosion (M25 brass fittings preferred); coating (powder paint) for damage; drainage holes free from obstruction; replace critical parts as needed (simple replacement with screwdriver possible)
Visual: check luminous intensity (comparison with similar luminaires); spectral/color temperature check (maintain CRI ≥80, no color cast); measurement point: check target area (50 lux emergency areas, higher for work areas); operating hours > 100,000 h → prepare for replacement (LED modules interchangeable)
Measure input voltage (check rated voltage, e.g. 220–254V AC); check for voltage spikes/fluctuations (no stability = electronics risk); check safety switches/contacts for wear; exclude temporary power supply (construction phase) → only permanent connections permitted
Type-general inspection and maintenance points for this equipment category — not model-specific.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →