TKF/TKD

S7-FR 2Cx10mm2 0.6/1kV

TKF/TKD S7-FR 2Cx10mm2 0.6/1kV is listed in the source as a marine Fire Resistant Cable (FRHF) within the Cable & Wiring group. Equipment of this type is typically installed through cable trays, trunks, penetrations and local equipment runs between switchboards, control panels, machinery and accommodation or safety systems. Its primary duty is carrying electrical power, control or communication signals for the service represented by the Fire Resistant Cable (FRHF), and it depends on conductor continuity, insulation integrity, correct termination, mechanical protection and approved fire or voltage characteristics remaining intact. The supplied entry records 10 mm² cross-section; these stated values should be retained when the unit is identified or compared with neighboring variants. It normally interfaces with switchboards, junction boxes, glands, penetrations, terminals, equipment enclosures and bonding or shielding arrangements as applicable. For any exact capacity, pressure, voltage, tolerance, wear limit or setting not stated in the source, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

cross section mm2 10
voltage class 0.6/1kV
cores 2
material Cu
insulation XLPE
fire rating IEC60331
halogen free True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Insulation damage caused by heat, oil, sharp edges, crushing or ageing can produce low insulation resistance, earth faults or protective trips
Loose or corroded terminations caused by vibration or moisture can create intermittent circuits, overheating or voltage drop
Water ingress through damaged glands or penetrations can lead to corrosion, insulation deterioration and recurring faults
Mechanical damage or unsupported runs caused by poor routing or disturbed clips can produce chafing, broken conductors or visible jacket damage
Incorrect replacement cable or compromised fire stopping after maintenance can leave the installation non-compliant even if electrical continuity appears normal

Service & Maintenance

Inspect routing, supports, bend areas, glands, penetrations, terminations and visible sheath condition. Test insulation, continuity or shielding only with methods suitable for the connected equipment and isolate sensitive electronics as required. Verify cable type and fire-stop restoration against approved drawings and manufacturer documentation.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Maintain approved cable lengths or repair material where the vessel's strategy requires them, together with correct glands, lugs, ferrules, identification sleeves, clips and certified penetration-sealing materials.
Equipment Model #86072 · ✓ still in production